threshold-type: Specifies a threshold type.
accumulate accumulate-occurrences: Specifies the total number of lost packets in the operation. The
value is in the range of 1 to 15000 for the UDP jitter operation and 1 to 60000 for the voice operation.
action-type: Specifies what action to be triggered. The default action is none.
none: Specifies the action of displaying results on the terminal display.
trap-only: Specifies the action of displaying results on the terminal display and meanwhile sending
SNMP trap messages to the NMS.
Usage guidelines
You cannot edit a reaction entry after it is created. To change the attributes in a reaction entry, use the
undo reaction command to delete the entry, and then configure a new one.
Examples
# Create reaction entry 1 for monitoring packet loss in the UDP jitter operation. Before the NQA
operation starts, the initial state of the reaction entry is invalid. After the operation, the total number of the
lost packets is checked against the threshold. If the number reaches or exceeds 100, the state of the
reaction entry is set to over-threshold. Otherwise, the state is set to below-threshold. Once the state of the
reaction entry changes, a trap message is generated and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element packet-loss
threshold-type accumulate 100 action-type trap-only

reaction checked-element probe-duration

Use reaction checked-element probe-duration to configure a reaction entry for monitoring the probe
duration.
Use undo reaction to delete the specified reaction entry.
Syntax
reaction
accumulate-occurrences | average | consecutive consecutive-occurrences } threshold-value
upper-threshold lower-threshold [ action-type { none | trap-only } ]
undo reaction item-number
Default
No reaction entry for monitoring the probe duration is configured.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP operation view
ICMP/UDP echo operation view
Predefined user roles
network-admin
Parameters
item-number: Assigns an ID to the reaction entry, in the range of 1 to 10.
item-number
checked-element
probe-duration
59
threshold-type
{
accumulate

Hide quick links: