HP MSR1003-8S Command Reference Manual page 218

Msr series network management and monitoring
Hide thumbs Also See for MSR1003-8S:
Table of Contents

Advertisement

Field
Sample type
Sampled variable
Sampling interval
Rising threshold
associated with event
Falling threshold
Alarm sent upon entry
startup
Latest value
Description
Sample type (MIB object alarmSampleType):
absolute—RMON compares the value of the variable with the rising and
falling thresholds at the end of the sampling interval.
delta—RMON subtracts the value of the variable at the previous sample from
the current value, and then compares the difference with the rising and falling
thresholds.
Monitored variable (MIB object alarmVariable).
Interval (in seconds) at which data is sampled and compared with the rising and
falling thresholds.
The MIB object for this field is alarmInterval.
Alarm rising threshold (MIB object alarmRisingThreshold).
A rising alarm is generated when the following conditions are all met:
The current sampled value is greater than or equal to this threshold.
The value at the previous sampling interval was less than this threshold.
A rising alarm is also generated when the following conditions are all met:
The first sample after this entry becomes valid is greater than or equal to this
threshold.
The associated alarmStartupAlarm instance is equal to risingAlarm or
risingOrFallingAlarm.
Event index (EventEntry) associated with the alarm:
MIB object alarmRisingEventIndex stores the event index that is used when the
rising threshold is crossed.
MIB object alarmFallingEventIndex stores the event index that is used when
the falling threshold is crossed.
Alarm falling threshold (MIB object alarmFallingThreshold).
A falling alarm is generated when the following conditions are all met:
The current sampled value is less than or equal to this threshold
The value at the previous sampling interval was greater than this threshold.
A falling alarm is also generated when the following conditions are met:
The first sample after this entry becomes valid is less than or equal to this
threshold.
The associated alarmStartupAlarm is equal to fallingAlarm or
risingOrFallingAlarm.
Alarm that can be generated when the entry becomes valid (MIB object
alarmStartupAlarm):
risingAlarm—Generates a rising alarm if the first sample after the entry
becomes valid is greater than or equal to the rising threshold.
fallingAlarm—Generates a falling alarm if the first sample after the entry
becomes valid is less than or equal to the rising threshold.
risingOrFallingAlarm—Generates a rising alarm or falling alarm if the first
sample after the entry becomes valid crosses the rising threshold or falling
threshold.
The default is risingOrFallingAlarm.
Most recent sampled value (MIB object alarmValue).
207