Reaction Checked-Element Icpif - HP MSR1003-8S Command Reference Manual

Msr series network management and monitoring
Hide thumbs Also See for MSR1003-8S:
Table of Contents

Advertisement

threshold-value: Specifies threshold range in milliseconds.
upper-threshold: Specifies the upper limit in the range of 0 to 3600000.
lower-threshold: Specifies the lower limit in the range of 0 to 3600000. It must not be greater than the
upper limit.
Usage guidelines
You cannot edit a reaction entry after it is created. To change the attributes in a reaction entry, use the
undo reaction command to delete the entry, and then configure a new one.
Only successful probe packets are monitored. Statistics about failed probe packets are not collected.
No actions can be configured for a reaction entry of monitoring one-way delays. To display the
monitoring results and statistics, use the display nqa reaction counters and display nqa statistics
commands.
Examples
# Create reaction entry 1 for monitoring the destination-to-source delay of every UDP jitter packet, and
set the upper limit to 50 milliseconds and lower limit to 5 milliseconds. Before the NQA operation starts,
the initial state of the reaction entry is invalid. The destination-to-source delay is calculated after the
response to the probe packet arrives. If the delay exceeds the upper limit, the state of the reaction entry
is set to over-threshold. If it is below the lower limit, the state is set to below-threshold. Once the state of
the reaction entry changes, a trap message is generated and sent to the NMS.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Sysname-nqa-admin-test-udp-jitter] reaction 1 checked-element owd-ds threshold-value 50
5

reaction checked-element icpif

Use reaction checked-element icpif to configure a reaction entry for monitoring the ICPIF value in the
voice operation.
Use undo reaction to delete the specified reaction entry.
Syntax
reaction
item-number
[ action-type { none | trap-only } ]
undo reaction item-number
Default
No reaction entry for monitoring ICPIF values is configured.
Views
Voice operation view
Predefined user roles
network-admin
Parameters
item-number: Assigns an ID to the reaction entry, in the range of 1 to 10.
threshold-value: Specifies threshold range.
checked-element
icpif
56
threshold-value
upper-threshold
lower-threshold