Statistics Max-Group - HP MSR1003-8S Command Reference Manual

Msr series network management and monitoring
Hide thumbs Also See for MSR1003-8S:
Table of Contents

Advertisement

Default
The interval is 60 minutes.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP/voice operation view
ICMP/UDP echo operation view
Path/UDP jitter operation view
Predefined user roles
network-admin
Parameters
interval: Specifies the interval in minutes, in the range of 1 to 35791394.
Usage guidelines
NQA forms statistics within the same collection interval as a statistics group. To display information
about the statistics groups, use the display nqa statistics command.
Examples
# Configure the system to collect the ICMP echo operation statistics at 2-minute intervals.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics interval 2

statistics max-group

Use statistics max-group to set the maximum number of statistics groups that can be saved.
Use undo statistics max-group to restore the default.
Syntax
statistics max-group number
undo statistics max-group
Default
A maximum of two statistics groups can be saved.
Views
DHCP/DLSw/DNS/FTP/HTTP/SNMP/TCP/voice operation view
ICMP/UDP echo operation view
Path/UDP jitter operation view
Predefined user roles
network-admin
Parameters
number: Specifies the maximum number of statistics groups, in the range of 0 to 100. To disable statistics
collection, set the value to 0.