7.3 Program Table Operation
7.3.5 SigmaWin+ Procedures
 Editing Procedures
The following two ways are used to edit the program table.
Note: The method that is used depends on the item.
• Items That Are Entered Directly
Click the cell to edit the item. Enter the setting directly.
• Items with Dialog Boxes
Double-click the cell to display the dialog box for editing. Make the settings in the dialog box.
Displays the
current setting.
Setting procedures are provided below for each item.
 POS
Set the target positions.
1.
Double-click the cell to edit.
The Target Position Reservation Dialog Box will be displayed.
2.
Set the target position and the position/distance.
Information
7-16
The Position/Distance setting is enabled when you set the target position to an absolute
position or relative distance.