8.1 Alarm Displays
8.1.2 Troubleshooting Alarms
Alarm Number:
Alarm Name
A.C52:
Polarity
Detection
Not
Completed
A.C53:
Out of Range of
Motion for Polar-
ity Detection
A.C54:
Polarity
Detection
Failure 2
A.C80:
Encoder Clear
Error or Multiturn
Limit Setting Error
8-28
Possible Cause
The servo was turned
ON under the follow-
ing circumstances.
• When an absolute
scale was in use
• When polarity
detection was not
completed
The travel distance
exceeded the setting
of Pn48E (Polarity
Detection Range) in
the middle of detec-
tion.
An external force was
applied to the Servo-
motor.
A failure occurred in
the encoder.
A failure occurred in
the SERVOPACK.
Confirmation
Execute polarity detec-
tion (with the SigmaWin+
or Digital Operator,
Fn080).
Increase the setting of
Pn48E (Polarity Detection
Range). Or, increase the
setting of Pn481 (Polarity
Detection Speed Loop
Gain).
Increase the setting of
Pn495 (Polarity Detection
Confirmation Force Refer-
ence). Increase the setting
of Pn498 (Polarity Detec-
tion Allowable Error
Range). Increasing the
allowable error will also
increase the motor tem-
perature.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the Servomotor or
linear encoder may be
faulty. Replace the Servo-
motor or linear encoder.
Turn the power supply to
the SERVOPACK OFF and
ON again. If an alarm still
occurs, the SERVOPACK
may be faulty. Replace the
SERVOPACK.
Continued from previous page.
Correction
Reference
*1
Continued on next page.