9.2 List of Parameters
9.2.2 List of Parameters
Parameter
No.
Pn00A
Pn00B
9-10
Name
Application Function
2
Selections A
Motor Stopping Method for Group 2 Alarms
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.
Stopping Method for Forced Stops
Apply the dynamic brake or coast the motor to a stop (use the
0
stopping method set in Pn001 = n.X).
Decelerate the motor to a stop using the torque set in Pn406 as
1
the maximum torque. Use the setting of Pn001 = n.X for the
status after stopping.

n.
X
Decelerate the motor to a stop using the torque set in Pn406 as
2
the maximum torque and then let the motor coast.
Decelerate the motor to a stop using the deceleration time set in
3
Pn30A. Use the setting of Pn001 = n.X for the status after
stopping.
Decelerate the motor to a stop using the deceleration time set in
4
Pn30A and then let the motor coast.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Application Function
2
Selections B
Operator Parameter Display Selection

n.
X
0
Display only setup parameters.
1
Display all parameters.
Motor Stopping Method for Group 2 Alarms
0
Stop the motor by setting the speed reference to 0.

n.
X
Apply the dynamic brake or coast the motor to a stop (use the
1
stopping method set in Pn001 = n.X).
2
Set the stopping method with Pn00A = n.X.
Power Input Selection for Three-phase SERVOPACK
0
Use a three-phase power supply input.

n.
X
Use a three-phase power supply input as a single-phase power
1
supply input.

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h
to
0001
h
0044
h
0000h
to
0000
h
1121
h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Reference
After
All
Setup
restart
Reference
Reference
Reference
Continued on next page.
Refer-
ence
*1
*1
*1
*1
*1