SigmaWin+
Menu Bar
Name [Unit]
Button
Polarity Sensor Signal Monitor
Status
Active Gain Monitor
Monitor
Safety I/O Signal Monitor
Input
Signal
Input Signal Monitor
Monitor
Output
Signal
Output Signal Monitor
Monitor
Installation Environment Monitor −
SERVOPACK
Installation Environment Monitor −
*2
Servomotor
Service Life Prediction Monitor −
Service
Built-in Fan
Life
Service Life Prediction Monitor −
Monitor
Capacitor
Service Life Prediction Monitor −
Surge Prevention Circuit
Service Life Prediction Monitor −
Dynamic Brake Circuit
Product
Motor − Resolution
Informa-
tion
*1.
You can use Un010 to monitor the upper limit setting for the maximum motor speed or the upper limit setting for
the encoder output resolution.
You can monitor the upper limit of the encoder output resolution setting (Pn281) for the current maximum motor
speed setting (Pn385), or you can monitor the upper limit of the maximum motor speed setting for the current
encoder output resolution setting.
Select which signal to monitor with Pn080 = n.X (Calculation Method for Maximum Speed or Divided Out-
put Pulses).
• If Pn080 = n.0, the encoder output resolution (Pn281) that can be set is displayed.
• If Pn080 = n.1, the maximum motor speed (Pn385) that can be set is displayed in mm/s.
*2.
This applies to the following motors. The display will show 0 for all other models.
SGM7J, SGM7A, SGM7P, SGM7G, and SGMCV
10.1 Corresponding SERVOPACK and SigmaWin+ Function Names
10.1.2 Corresponding SERVOPACK Monitor Display Function Names
Un No.
Un011
Polarity Sensor Signal Monitor
Effective Gain Monitor (gain settings 1 = 1, gain
Un014
settings 2 = 2)
Un015
Safety I/O Signal Monitor
Un005
Input Signal Monitor
Un006
Output Signal Monitor
SERVOPACK Installation Environment Monitor
Un025
[%]
Servomotor Installation Environment Monitor
*2
Un026
[%]
Un027
Built-in Fan Remaining Life Ratio [%]
Un028
Capacitor Remaining Life Ratio [%]
Surge Prevention Circuit Remaining Life Ratio
Un029
[%]
Un02A
Dynamic Brake Circuit Remaining Life Ratio [%]
Linear Encoder Pitch (Scale pitch = Un084 ×
Un084
Un085
10
[pm])
Linear Encoder Pitch Exponent (Scale pitch =
Un085
Un084 × 10
Un020
Rated Motor Speed [min
Un021
Maximum Motor Speed [min
Continued from previous page.
SERVOPACK
Name [Unit]
Un085
[pm])
-1
]
-1
]
10
10-5