Resetting Program Table Operation
In this example, program operation is reset during repeated operation of program steps 0 and 1
and then the program step is specified and operation is restarted from the canceled state.
Note: "Canceled" is the state in which the mode is mode 0, execution is not in a stopped state, and no program
step has been executed.
Step 0 performs relative positioning for 100,000 reference units at a speed of 15,000,000 refer-
ences units/min. The acceleration rate is 400,000,000 reference units/min/ms and the deceler-
ation rate is 200,000,000 reference units/min/ms.
Step 1 performs relative positioning for 100,000 reference units at a speed of 30,000,000 refer-
ences units/min. The acceleration rate is 400,000,000 reference units/min/ms and the deceler-
ation rate is 200,000,000 reference units/min/ms.
The program table for this positioning is shown below.
PGM-
POS
SPD
STEP
0
I+100000
15000
1
I-100000
30000
• Operating Procedure
Turn ON the /MODE 0/1 signal to change to mode 0.
Set the /SEL0 to /SEL4 signals to 0 to specify program step 0.
Turn ON the /START-STOP signal to start program table operation.
Turn OFF the /START-STOP signal to stop program table operation.
Turn ON the /PGMRES signal to cancel program table operation.
Set the /SEL0 to /SEL4 signals to 1 (i.e., turn ON /SEL0) to specify program step 1.
Turn ON the /START-STOP signal to start program table operation.
When positioning is completed to the target position, the /COIN signal turns ON.
• Operation Pattern and Related Signal Timing
peed
Operation
Pattern
MODE 0 (program table operation)
/MODE 0/1
1 m min.
/ TART- TOP*
/PGMRE
1 m min.
/ EL0 to
/ EL4*
/COIN
*
Do not change /SEL0 to /SEL7 for 4 ms after turning ON the /START-STOP signal.
RDST
RSPD
ACC
1000
400000 200000
1000
400000 200000
tep 0
Canceled tate
1 m min.
1 m min.
1 m min.
0
7.3 Program Table Operation
7.3.7 Program Table Operation Examples
DEC
POUT
EVENT
NNNNN-
IT1000
NNN
NNNNN-
IT1000
NNN
tep 1
1
LOOP
NEXT
1
1
1
0
Time