Combining Positioning with Constant-Speed Operation
This example shows how to perform operation that combines constant-speed operation and
positioning when the target position (POS) is set to INFINITE.
Step 0 performs operation for 2 seconds with no target position (infinite length = INFINITE) at a
speed of 15,000,000 reference units/min.
Step 1 performs operation with no target position (infinite length = INFINITE) and changes the
speed from 15,000,000 reference units/min to 30,000,000 reference units/min. Operation con-
tinues until the /SEL0 signal turns ON.
Step 2 decelerates the motor to a stop and step 3 performs relative positioning from the stop
position to a target position of 200,000 reference units.
PGM-
POS
SPD
STEP
0
+INFINITE
15000
1
+INFINITE
30000
2
STOP
30000
3
I+200000
30000
• Operating Procedure
Turn ON the /MODE 0/1 signal to change to mode 0.
Set the /SEL0 to /SEL4 signals to 0 to specify program step 0.
Turn ON the /START-STOP signal to start program table operation.
The /COIN signal turns OFF.
After 2 seconds elapse, step 1 is executed.
When the /SEL0 signal turns ON, step 2 is executed.
After the motor decelerates to a stop, the /COIN signal turns ON and step 3 is executed.
At the start of execution, the /COIN signal turns OFF.
When positioning is completed to the target position, the /COIN signal turns ON.
When the /SEL1 signal turns ON, program step 3 is ended and program step 0 is exe-
cuted.
• Operation Pattern and Related Signal Timing
tep 0
peed
Operation
Pattern
2
Mode 0 (Program Table Operation)
/MODE 0/1
1 m min.
TART- TOP*
1 m min.
/ EL0 to
/ EL4*
/COIN
*
Do not change /SEL0 to /SEL7 for 4 ms after turning ON the /START-STOP signal.
RDST
RSPD
ACC
-
1000
400000 200000 NNNNN
-
1000
:
-
1000
:
-
1000
:
tep 2
tep
tep 1
1 m min.
0
1
7.3 Program Table Operation
7.3.7 Program Table Operation Examples
DEC
POUT
EVENT
T2000
:
:
SEL0T0
:
:
IT0
:
:
SEL1T0
tep 2
tep 0
tep 1
2
1 m min.
1 m min.
2
LOOP
NEXT
1
1
1
2
1
3
1
0
tep
Time
1
7
7-35