7.3 Program Table Operation
7.3.5 SigmaWin+ Procedures
Saving the Program Table
 Saving the Program Table to Flash Memory in the SERVOPACK
To prevent the program table from being deleted when the power supply to the SERVOPACK is
turned OFF, you must save it to flash memory in the SERVOPACK. The program table that is
saved in the flash memory is automatically loaded each time the power supply is turned ON.
We recommend that you save the program table that is normally used for operation in this flash
memory.
There are the following two ways to save the program table to flash memory in the SERVO-
PACK.
• Save it from the Edit Program Dialog Box.
• Save it with Fn060 (Edit/Save Program Table) on a Digital Operator.
Use the following procedure to save the program table from the Edit Program Dialog Box.
1.
Click the Save Button in the Program Table Editing Dialog Box.
The Save Table Dialog Box will be displayed.
2.
Click the OK Button.
This concludes the saving procedure.
7-24