9.2 List of Parameters
9.2.2 List of Parameters
Parameter
No.
Pn002
9-6
Name
Application Function
2
Selections 2
Speed/Position Control Option (T-REF Input Allocation)
0
Do not use T-REF.

1
Use T-REF as an external torque limit input.
n.
X
2
Use T-REF as a torque feedback input.
Use T-REF as an external torque limit input when
3
/P-CL or /N-CL is ON.
Torque Control Option (V-REF Input Allocation)

n.
X
0
Do not use V-REF.
1
Use V-REF as an external speed limit input.
Encoder Usage
Use the encoder according to encoder specifica-
0
tions.

n.
X
1
Use the encoder as an incremental encoder.
Use the encoder as a single-turn absolute
2
encoder.
External Encoder Usage
0
Do not use an external encoder.
The external encoder moves in the forward direc-
1
tion for CCW motor rotation.

n.X
2
Reserved setting (Do not use.)
The external encoder moves in the reverse direc-
3
tion for CCW motor rotation.
4
Reserved setting (Do not use.)
Setting
Setting
Default
Range
Unit
Setting
0000h
to
0000h
4213
h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
Setup
restart
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
Applicable
Reference
Motors
All
Rotary
Applicable
Reference
Motors
Rotary
Continued on next page.
Refer-
ence
*1
*1
*1
*1
*1
*1

Hide quick links: