Parameter
Name
No.
Application Function
2
Selections 8
Low Battery Voltage Alarm/Warning Selection
n.
X
Function Selection for Undervoltage
Pn008
n.
X
Warning Detection Selection
n.
X
n.X
Reserved parameter (Do not change.)
Application Function
2
Selections 9
n.
X
Reserved parameter (Do not change.)
Current Control Mode Selection
n.
X
Pn009
Speed Detection Method Selection
n.
X
n.X
Reserved parameter (Do not change.)
Setting
Setting
Range
Unit
0000h
to
–
7121
h
0
Output alarm (A.830) for low battery voltage.
1
Output warning (A.930) for low battery voltage.
0
Do not detect undervoltage.
1
Detect undervoltage warning and limit torque at host controller.
Detect undervoltage warning and limit torque with Pn424 and
2
Pn425 (i.e., only in SERVOPACK).
0
Detect warnings.
1
Do not detect warnings except for A.971.
0000h
to
–
0121
h
0
Use current control mode 1.
• SERVOPACK Models SGD7S-R70A, -R90A, -1R6A, -2R8A,
-3R8A, -5R5A, and -7R6A: Use current control mode 1.
1
• SERVOPACK Models SGD7S-120A, -180A, -200A, -330A,
-470A, -550A, -590A, and -780A: Use current control mode 2.
2
Use current control mode 2.
0
Use speed detection 1.
1
Use speed detection 2.
9.2 List of Parameters
9.2.2 List of Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0000h
Rotary
restart
After
0010
h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
–
Reference
*1
Reference
*1
Reference
*1
Tuning
–
Reference
*1
Reference
*1
9
9-9