YASKAWA SGD7S-R70A Product Manual page 238

E-7-series ac servo drive e-7s servopack with ft/ex specification for indexing application
Hide thumbs Also See for SGD7S-R70A:
Table of Contents

Advertisement

9.2 List of Parameters
9.2.2 List of Parameters
Parameter
No.
Pn633
Pn634
9-38
Name
Input Signal Selections
2
13
/JOG1 (Jog Speed Table Selection Input 1) Signal Allocation
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).

n.
X
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/JOG2 (Jog Speed Table Selection Input 2) Signal Allocation

n.
X
The settings are the same as for /JOG1 (Jog Speed Table Selec-
0 to F
tion Input 1) Signal Allocation.

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Input Signal Selections
2
14
SI8 Signal Selection
0
Do not allocate an input signal to CN1-14 and CN1-15.
Allocate the CLR signal as the input signal to CN1-14 and CN1-
1
15.

n.
X
Allocate the /DEC signal as the input signal to CN1-14 and CN1-
2
15.
Allocate the /RGRT signal as the input signal to CN1-14 and
3
CN1-15.
SI8 Signal Selection Logic

n.
X
0
Active when CN1-14 and CN1-15 input signal is ON (closed).
1
Active when CN1-14 and CN1-15 input signal is OFF (open).

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
Setting
Setting
Default
Range
Unit
Setting
0000h to
8888h
FFFFh
0000h to
0002h
0013h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
page 6-3
Reference
page 6-3
After
All
Setup
restart
Reference
page 6-5
Reference
page 6-5
Continued on next page.
Refer-
ence

Hide quick links:

Advertisement

Table of Contents
loading