Symbols and Glossary
MiCOM P40 Agile P442, P444
Symbols
Explanation
Current raised to a power:
I
Such as when breaker statistics monitor the square of ruptured current squared
(
power = 2).
I/O
Abbreviation of "Inputs and Outputs":
Used in connection with the number of optocoupled inputs and output contacts within the relay.
I/P
Abbreviation of "Input".
I<
An undercurrent element:
Responds to current dropout.
I>
An overcurrent element:
Detects phase faults; Optionally used by the 50BF protection.
I>1
First stage of phase overcurrent protection:
Could be labelled 51-1 in ANSI terminology.
I>2
Second stage of phase overcurrent protection:
Could be labelled 51-2 in ANSI terminology.
I>3
Third stage of phase overcurrent protection:
Could be labelled 51-3 in ANSI terminology.
I>4
Fourth stage of phase overcurrent protection:
Could be labelled 51-4 in ANSI terminology.
I>BB
Minimum pick-up phase threshold for the local trip order confirmation.
I>DZ
Minimum pick-up phase threshold for the Dead Zone protection.
I
Zero sequence current:
0
Equals one third of the measured neutral/residual current.
I
Positive sequence current.
1
I
Negative sequence current.
2
I2>
Negative sequence overcurrent protection (NPS element).
I2pol
Negative sequence polarizing current.
IA
Phase A current:
Might be phase L1, red phase. or other, in customer terminology.
IB
Phase B current:
Might be phase L2, yellow phase. or other, in customer terminology.
IbiasPh>
SDEF blocking bias current threshold.
Cur.
IC
Phase C current:
Might be phase L3, blue phase. or other, in customer terminology.
ID
Abbreviation of "Identifier":
Often a label used to track a software version installed.
ID>1
Minimum pick-up phase circuitry fault threshold.
ID>2
Minimum pick-up differential phase element for all the zones.
IDCZ>2
Minimum pick-up differential phase element for the Check Zone.
IDMT
Inverse definite minimum time:
A characteristic whose trip time depends on the measured input (e.g. current) according to an
inverse-time curve.
IDN>1
Minimum pick-up neutral circuitry fault threshold.
IDN>2
Minimum pick-up differential neutral element for all the zones.
IDNCZ>2
Minimum pick-up differential neutral element for the Check Zone.
IDZ
Minimum pick-up differential neutral element for the Check Zone.
International Electrotechnical Commission (organization that prepares and publishes
IEC
International Standards for all electrical, electronic and related technologies)
P44x/EN SG/ Hb6
(SG) 13-5

Advertisement

Table of Contents
loading