GE MiCOM P40 Agile Technical Manual page 347

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

Programmable Logic
MiCOM 40 Agile P442, P444
Ordinal
English Text
1063
I>3 Timer Block
1064
I>4 Timer Block
1065
I2>1 Timer Block
1066
I2>2 Timer Block
1067
I2>3 Timer Block
1068
I2>4 Timer Block
1069
V<1 Timer Block
1070
V<2 Timer Block
1071
V<3 Timer Block
1072
V<4 Timer Block
1073
V>1 Timer Block
1074
V>2 Timer Block
1075
V>3 Timer Block
1076
V>4 Timer Block
1077
VN>1 Timer Block
1078
VN>2 Timer Block
Description
Block phase overcurrent stage 3 time delay
Set to 1: 'I>3 Time Delay' will be blocked & I>3 will start
but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase overcurrent stage 4 time delay
Set to 1: 'I>4 Time Delay' will be blocked & I>4 will start
but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block negative sequence overcurrent stage 1 time delay
Block negative sequence overcurrent stage 2 time delay
Block negative sequence overcurrent stage 3 time delay
Block negative sequence overcurrent stage 4 time delay
Block phase undervoltage stage 1 time delay
Set to 1: 'V<1 Time Delay' will be blocked and V<1 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase undervoltage stage 2 time delay
Set to 1: 'V<2 Time Delay' will be blocked and V<1 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase undervoltage stage 3 time delay
Set to 1: 'V<3 Time Delay' will be blocked and V<1 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase undervoltage stage 4 time delay
Set to 1: 'V<4 Time Delay' will be blocked and V<1 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase overvoltage stage 1 time delay
Set to 1: 'V>1 Time Delay will be blocked and V>1 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase overvoltage stage 2 time delay
Set to 1: 'V>2 Time Delay' will be blocked and V>2 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase overvoltage stage 3 time delay
Set to 1: 'V>3 Time Delay' will be blocked and V>3 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block phase overvoltage stage 4 time delay
Set to 1: 'V>4 Time Delay' will be blocked and V>4 will
start but will not issue any trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB cell
Block earth overvoltage stage 1 time delay
Block earth overvoltage stage 2 time delay
P44x/EN PL/Hb6
(PL) 6-27
Source
PSL (IN) I>3
PSL (IN) I>4
PSL (IN) I>4
PSL (IN) I>5
PSL (IN) I>6
PSL (IN) I>7
PSL (IN) V<1
PSL (IN) V<2
PSL (IN) V<3
PSL (IN) V<4
PSL (IN) V>1
PSL (IN) V>2
PSL (IN) V>3
PSL (IN) V>4
PSL (IN)
VN>1
PSL (IN)
VN>2

Advertisement

Table of Contents
loading

This manual is also suitable for:

P442P444

Table of Contents