Settings, Measurements And Records List; Global Settings (System Data); Distance Protection - GE MiCOM P40 Agile Technical Manual

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

Technical Data
MiCOM P40 Agile P442, P444
SETTINGS, MEASUREMENTS
AND RECORDS LIST
SETTINGS LIST

GLOBAL SETTINGS (SYSTEM DATA):

Language:
English/French/German/Spanish/Italian/
Chinese (ordering option)
Frequency: 50/60 Hz
CONFIGURATION
Setting Group:
Select via Menu
Select via Opto
Active Settings:
Setting Group 1:
Setting Group 2:
Setting Group 3:
Setting Group 4:

Distance Protection:

Power Swing:
Back-Up I>:
Negative Sequence
overcurrent:
Broken Conductor:
Earth Fault overcurrent
protection:
Zero sequence power/
Earth fault overcurrent
Aided Directional Earth
Fault (DEF):
Voltage Protection:
Circuit Breaker Fail & I<:
Supervision (Voltage,
Current or Capacitive
Voltage Transformer):
System Checks:
Thermal Overload:
I< Protection:
Residual Overvoltage
protection:
Frequency Protection:
Internal Autoreclose:
Input Labels:
Output Labels:
CT & VT Ratios:
Record Control:
Disturbance Recorder:
Measure't Setup:
Communication Settings:
Commission Tests:
Setting Values:
Control Input:
Control Input Config:
Control Input Labels:
Direct Acces:
InterMiCOM:
Ethernet NCIT:
Function key:
RP1 / RP2 Read only
NIC Read only
PSL Timers:
RearPortt1ReadOnly
RearPort2ReadOnly
RearNICReadOnly
LCD Contrast:
Group 1/2/3/4
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
Invisible/Visible
Invisible/Visible
Invisible/Visible
Invisible/Visible
Invisible/Visible
Invisible/Visible
Invisible/Visible
Invisible/Visible
Primary/Secondary
Invisible/Visible
Invisible/Visible
Invisible/Visible
Disabled/Enabled
Disabled/Enabled
Invisible/Visible
Invisible/Visible
Disabled/Enabled
Disabled/Enabled
Invisible/Visible
Disabled/Enabled
Disabled/Enabled
Disabled/Enabled
(Factory pre-set)
DISTANCE PROTECTION
Line setting
Line Length (Ln): 0.3 to 1000 km (step 0.010)
or 0.2 to 625 miles (step 0.005)
Line Impedance:
0.001×I1 to 500×I1 (step 0.001×I1)
Positive sequence angle (Line Angle, ϑ
–90.0° to +90° (step 0.1°)
Zone setting
Zone Status:
∗ Z1X
∗ Z2
∗ ZP
∗ ZQ
∗ Z3
∗ Z4
Z1 (Impedance reach:) 0.001/In to 500/In Ω
Z1X
kZ1 residual
compensation factor:
KZ1 residual
compensation angle:
R1G (Resistive reach for
phase-earth fault):
0 Ω to 400/In Ω (step 0.01/In Ω)
R1Ph (Resistive reach
for phase-phasefault):
0 Ω to 400/In Ω (step 0.01/In Ω)
tZ1 (time-delay
for Zone 1):
0 to 10 s (step 0.002 s)
0.001/In to 500/In Ω (step 0.001/In/Ω)
Z2:
kZ2 res comp:
kZ2 Angle:
0 Ω to 400/In Ω (step 0.01/In Ω)
R2G:
0 Ω to 400/In Ω (step 0.01/In Ω)
R2Ph:
tZ2:
0 to 10 s (step 0.002 s)
0.001/In to 500/In Ω (step 0.001/In/Ω)
Z3:
kZ3/4 res comp:
kZ3/4 Angle:
0 Ω to 400/In Ω (step 0.01/In Ω)
R3G-R4G:
R3Ph-R4Ph: 0 Ω to 400/In Ω (step 0.01/In Ω)
tZ3:
0 to 10 s (step 0.002 s)
0.001/In to 500/In Ω (step 0.01/In Ω)
Z4:
tZ4:
0 to 10 s (step 0.01 s)
Zone P – Directionality
0.001/In to 500/In Ω (step 0.001/In/Ω)
Zp:
kZp res comp:
kZp Angle:
0 Ω to 400/In Ω (step 0.01/In Ω)
RpG:
0 Ω to 400/In Ω (step 0.01/In Ω)
RpPh:
tZp:
0 to 10 s (step 0.002 s)
Zone Q – Directionality
0.001/In to 500/In Ω (step 0.001/In/Ω)
Zq:
kZq res comp:
kZq Angle:
0 Ω to 400/In Ω (step 0.01/In Ω)
RqG:
0 Ω to 400/In Ω (step 0.01/In Ω)
RqPh:
tZq:
0 to 10 s (step 0.002 s)
P44x/EN TD/Hb6
(TD) 2-13
):
1
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
Enabled/Disabled
(step 0.001/In Ω)
0.001/In to 500/In Ω
(step 0.001/In Ω)
0 to 7 (step 0.001)
0 to +360° (step 0.1°)
0 to 7 (step 0.001)
0 to 360° (step 0.1°)
0 to 7 (step 0.001)
0 to 360° (step 0.1°)
Forward/Reverse
0 to 7 (step 0.001)
0 to 360° (step 0.1°)
Forward/Reverse
0 to 7 (step 0.001)
0 to 360° (step 0.1°)