Programmable Logic
MiCOM 40 Agile P442, P444
Ordinal
English Text
352
Out Of Step Conf
353
S. Swing Conf
354
Dist Start N
355
IN>3 Trip
356
IN>4 Trip
357
IN>3 Start
358
IN>4 Start
359
PAP Trip A
360
PAP Trip B
361
PAP Trip C
362
PAP Trip IN
363
PAP Start A
364
PAP Start B
365
PAP Start C
366
PAP Pres IN
367
PAP Pre Start
368
Trace Trig OK
369
Thermal Alarm
370
Trip Thermal
371
V<1 Start A
372
V<1 Start B
373
V<1 Start C
374
V<2 Start A
375
V<2 Start B
376
V<2 Start C
377
V>1 Start A
378
V>1 Start B
379
V>1 Start C
380
V>2 Start A
381
V>2 Start B
382
V>2 Start C
383
I2>2 Start
384
I2>3 Start
385
I2>4 Start
386
I2>2 Trip
387
I2>3 Trip
388
I2>4 Trip
389
VN>1 Start
390
VN>2 Start
391
VN>1 Trip
392
VN>2 Trip
393
Any Int. Trip
394
Zq
395
Tzq
Description
Out of Step Confirmed (number of cycles reached)
Stable Swing confirmed (number of cycles reached)
Start of distance protection for phase to ground fault
Trip decision from IN>3 function (timer issued)
Default PSL: Relay 09
Trip decision from IN>4 function (timer issued)
Start of IN>3 function (timer initiated)
Start of IN>4 function (timer initiated)
Trip A Phase decision from PAP (specific application)
function
Trip B Phase decision from PAP (specific application)
function
Trip C Phase decision from PAP (specific application)
function
Trip decision from PAP (specific application) function
(Ground Fault detected)
Phase A Start with PAP (specific application) function
Phase B Start with PAP (specific application) function
Phase C Start with PAP (specific application) function
Residual current detected by PAP (specific application)
function
PAP (specific application) Picks up by voltage detectors
(timer initiated)
Triggering trace has operated correctly
Alarm from Thermal Overload function picks up
Trip with Thermal Overload fucntion (timer issued)
Undervoltage stage 1 pick up on phase A
Undervoltage stage 1 pick up on phase B
Undervoltage stage 1 pick up on phase C
Undervoltage stage 2 pick up on phase A
Undervoltage stage 2 pick up on phase B
Undervoltage stage 2 pick up on phase C
Overvoltage stage 1 pick up on phase A
Overvoltage stage 1 pick up on phase B
Overvoltage stage 1 pick up on phase C
Overvoltage stage 2 pick up on phase A
Overvoltage stage 2 pick up on phase B
Overvoltage stage 2 pick up on phase C
Negative overcurrent stage 2 pick-up
Negative overcurrent stage 3 pick-up
Negative overcurrent stage 4 pick-up
Negative overcurrent stage 2 trip
Negative overcurrent stage 3 trip
Negative overcurrent stage 4 trip
Neutral overvoltage stage 1 pick up
Neutral overvoltage stage 2 pick up
Neutral overvoltage stage 1 trip
Neutral overvoltage stage 2 trip
Any Internal trip
Fault in zone Q
Timer in zone Q elapsed (at 1 = end of timer)
P44x/EN PL/Hb6
(PL) 6-17
Source
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL