P44x/EN PL/Hb6
(PL) 6-30
Ordinal
English Text
1544 to
--
2047
1672 to
LN1 Analog Alarm
1677
to
LN6 Analog Alarm
1680 to
LN1 Test Mode to
1685
LN6 Test Mode
1688 to
LN1 Async to
1693
LN6 Async
1696 to
LN1 Val Quest to
1701
LN6 Val Quest
1704 to
LN1 Val Fail to
1709
LN6 Val Fail
1.1.2
Sorted by name
Ordinal
English Text
1111
103 CommandBlock
1110
103 MontorBlock
328
1P Trip
318
1ph Fault
319
2ph Fault
329
3P Trip
320
3ph Fault
224
A/R 1P In Prog
226
A/R 1st In Prog
Description
Unused (except next DDBs for specific options)
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
If two consecutive of any Logical Node frames have not
been received within the Merge Unit Delay set
parameter (time of silence in the reception of the frame),
the LN is "absent"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
Any Logical Node is in "Test Mode"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
Any Logical Node is synchronized with Internal (local)
synchronization
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
The sample value (SV) transmitted status from the LN is
"questionable"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
The sample value (SV) transmitted status from the LN is
"failed"
Description
For IEC-870-5-103 protocol only, used for "Command
Blocking" (relay ignores SCADA commands)
For IEC-870-5-103 protocol only, used for "Monitor
Blocking" (relay is quiet - issues no messages via
SCADA port)
Single pole trip (internal or external)
Single phase fault
Two phase fault
Three pole trip (internal or external)
Three phase fault
One-pole autoreclose cycle in progress: A single pole
autoreclose cycle is in progress. This output will remain
activated from the initial protection trip until the circuit
breaker is closed successfully or the autoreclose
function is Locked Out, indicating that a dead time
timeout is in progress. This signal may be useful during
relay commissioning to check the operation of the
autoreclose cycle.
First high speed autoreclose cycle in progress: Used to
indicate the autorecloser is timing out its first dead
time, either a high-speed single-pole shot or a high
speed three-pole shot.
Programmable Logic
MiCOM 40 Agile P442, P444
Source
PSL
PSL
PSL
PSL
PSL
PSL
Source
PSL
PSL
PSL (OUT)
All protection
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
All protection
PSL (OUT)
Distance
PSL (OUT)
Autorecloser
PSL (OUT)
Autorecloser