GE MiCOM P40 Agile Technical Manual page 368

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

P44x/EN PL/Hb6
(PL) 6-48
Ordinal
English Text
64
Opto Label 01
65
Opto Label 02
Opto Label 03 to
66 to 95
Opto Label 32
350
Out Of Step
352
Out Of Step Conf
700 to
Output cond. 1 to
763
Output cond. 64
367
PAP Pre Start
366
PAP Pres IN
363
PAP Start A
364
PAP Start B
365
PAP Start C
1089
PAP TeleT. Heath
1088
PAP TeleTrip CR
1090
PAP Timer Block
359
PAP Trip A
360
PAP Trip B
361
PAP Trip C
362
PAP Trip IN
269
Power Swing
175
Prot'n Disabled
1480 to
PubPres VIP 1 to
1543
PubPres VIP 64
1353 to
Quality VIP 1 to
1415
Quality VIP 64
Description
OPTO ISOLATOR 1
Set to 1 when the opto input is energised for a
minimum time: 7ms (48Vdc), 10ms (universal) to be
validated by internal logic
To enable the selection of a setting group by state
change of the opto isolated logic inputs 1 and 2,
disconnect Opto inputs 01 and 02 in the PSL (Opto
inputs 01 and 02 must not be connected to any output
signal)
OPTO ISOLATOR 2
Set to 1 when the opto input is energised for a
minimum time: 7ms (48Vdc), 10ms (universal) to be
validated by internal logic
To enable the selection of a setting group by state
change of the opto isolated logic inputs 1 and 2,
disconnect Opto inputs 01 and 02 in the PSL (Opto
inputs 01 and 02 must not be connected to any output
signal)
OPTO ISOLATOR 3 to
OPTO ISOLATOR 32
Set to 1 when the opto input is energised for a
minimum time:7ms (48Vdc), 10ms (universal) to be
validated by internal logic
Start of an Out of Step Detection (1st cycle), The first
out of step cycle has been detected (Zlocus in/out with
the opposite R sign) & the « Out Of Step start » picks-
up
Out of Step Confirmed (number of cycles reached)
Input to Relay Output Conditioner
PAP (specific application) Picks up by voltage
detectors (timer initiated)
Residual current detected by PAP (specific application)
function
Phase A Start with PAP (specific application) function
Phase B Start with PAP (specific application) function
Phase C Start with PAP (specific application) function
PAP (specific application) Carrier Out of Service (DT
trip decision)
PAP (specific application) Carrier Receive for
teletransmission
Timer Block for frozen every timer initiated with PAP
(specific application) function
Trip A Phase decision from PAP (specific application)
function
Trip B Phase decision from PAP (specific application)
function
Trip C Phase decision from PAP (specific application)
function
Trip decision from PAP (specific application) function
(Ground Fault detected)
Power swing detected (3 single phase loop inside the
quad & crossing the ∆R band in less than 5ms in a 50
Hz network). Power swing is present either with out of
step cycle or stable swing cycle.
Protection is disabled and test mode enabled
Publishing presence of virtual input 1 (to 64): indicates
virtual input 1 (to 64) presence.
Validation of the virtual input 1 (to 64)
(signal correct).
Programmable Logic
MiCOM 40 Agile P442, P444
Source
OPTO
OPTO
OPTO
PSL (OUT)
PSL (OUT)
PSL
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL(IN)
PSL(IN)
PSL(IN)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
PSL (OUT)
Distance
PSL (OUT)
PSL
PSL