GE MiCOM P40 Agile Technical Manual page 363

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

Programmable Logic
MiCOM 40 Agile P442, P444
Ordinal
English Text
386
I2>2 Trip
384
I2>3 Start
1067
I2>3 Timer Block
387
I2>3 Trip
385
I2>4 Start
1068
I2>4 Timer Block
388
I2>4 Trip
485
IM Channel Fail
484
IM Data CD Fail
482
IM Loopback
483
IM Message Fail
283
IN>1 Start
1056
IN>1 Timer Block
281
IN>1 Trip
284
IN>2 Start
1057
IN>2 Timer Block
282
IN>2 Trip
357
IN>3 Start
1058
IN>3 Timer Block
355
IN>3 Trip
358
IN>4 Start
1059
IN>4 Timer Block
356
IN>4 Trip
Description
Negative overcurrent stage 2 trip
Negative overcurrent stage 3 pick-up
Block negative sequence overcurrent stage 3 time
delay
Negative overcurrent stage 3 trip
Negative overcurrent stage 4 pick-up
Block negative sequence overcurrent stage 4 time
delay
Negative overcurrent stage 4 trip
InterMiCOM message channel fail
InterMiCOM data channel detect fail
InterMiCOM indication that loopback testing is in
progress
InterMiCOM message failure alarm
Earth fault stage 1 start – Start function (the associated
time-delay picks up)
Directional or not - with DT or IDMT curves
Negative or positive sequence polarization
Set to 0: Reset with IN below the threshold IN>1
Hysteresis
Block earth fault stage 1 time delay
Set to 1: 'IN>1 Time Delay' will be blocked & IN>1 will
start but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB
cell
Earth fault stage 1 trip
issued when the associated time-delay has elapsed
Earth fault stage 2 start – Start function (the associated
time-delay picks up)
Directional or not - with DT or IDMT curves
Negative or positive sequence polarization
Set to 0: Reset with IN below the threshold IN>2
Hysteresis
Block earth fault stage 2 time delay
Set to 1: 'IN>2 Time Delay' will be blocked & IN>2 will
start but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB
cell
Earth fault stage 2 trip – 3-pole trip command issued
when the associated time-delay has elapsed
Default PSL: Relay 09.
Start of IN>3 function (timer initiated)
Block earth fault stage 3 time delay
Set to 1: 'IN>3 Time Delay' will be blocked & IN>3 will
start but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB
cell
Trip decision from IN>3 function (timer issued)
Default PSL: Relay 09
Start of IN>4 function (timer initiated)
Block earth fault stage 4 time delay
Set to 1: The IN>4 time-delay will be blocked & IN>4
will start but will not issue any trip command.
Reset to 0: opto input power off if signal assigned to an
opto input OR DDB at 0 if signal assigned to a DDB
cell
Trip decision from IN>4 function (timer issued)
– 3-pole trip command
P44x/EN PL/Hb6
(PL) 6-43
Source
PSL
PSL
PSL (IN) I>6
PSL
PSL
PSL (IN) I>7
PSL
PSL(OUT)
PSL(OUT)
PSL(OUT)
PSL(OUT)
PSL (OUT)
Earth Fault 1
PSL (IN)
Earth Fault
PSL (OUT)
Earth Fault 1
PSL (OUT)
Earth Fault 2
PSL (IN)
Earth Fault
PSL (OUT)
Earth Fault 2
PSL (OUT)
PSL (IN)
Earth Fault
PSL (OUT)
PSL (OUT)
PSL (IN)
Earth Fault
PSL (OUT)