P44x/EN PL/Hb6
(PL) 6-12
Ordinal
English Text
251
DIST Start C
252
DIST Sch. Accel.
253
DIST Sch. Perm.
254
DIST Sch. Block.
255
Z1
256
Z1X
257
Z2
258
Z3
259
Z4
260
Zp
261
T1
262
T2
263
T3
264
T4
265
Tzp
266
WI Trip A
267
WI Trip B
268
WI Trip C
269
Power Swing
270
Reversal Guard
Description
Distance protection started on phase C
Set to 0: Reset of (R, X) (resistance, reactance)
calculation made by All pole Dead detection:
– I Dead: Fourier algorithm calculation (3 or 4 samples
requested)
– V Dead calculated by CB Fail (More than 10 ms
requested)
Distance scheme Accelerating
Distance scheme Permissive
Distance scheme Blocking
Fault in zone 1 (convergence of loop in Z1)
Set to 0: Reset of (R, X) (resistance, reactance)
calculation made by All pole Dead detection
(default PSL: LED 5, Relays 01 / 10)
Fault in zone 1 extended Z1x (convergence of loop in
Z1x) and filtered by blocking/unblocking Power
Swing/Reversal guard logic (default PSL: LED 5, Relay
10)
Fault in zone 2 (convergence of loop in Z2) and filtered
by blocking/unblocking Power Swing/Reversal guard
logic
logic (default PSL: LED 5, Relay 10)
Fault in zone 3 (convergence of loop in Z3) and filtered
by blocking/unblocking Power Swing/Reversal guard
logic
logic (default PSL: LED 5, Relay 10)
Fault in zone 4 (convergence of loop in Z4) and filtered
by blocking/unblocking Power Swing/Reversal guard
logic
logic (default PSL: LED 5, Relay 10)
Fault in zone P Zp (convergence of loop in Zp)
logic (default PSL: LED 5, Relay 10)
Distance time-delay in zone 1 tZ1 elapsed (1 = end of
timer)
If T1=0 picks up when the relay starts (Distance Start or
preset)
Distance time-delay in zone 2 tZ2 elapsed (1 = end of
timer)
Distance time-delay in zone 3 tZ3elapsed (1 = end of
timer)
Distance time-delay in zone 4 tZ4 elapsed (1 = end of
timer)
Distance time-delay in zone p tZp elapsed (1 = end of
timer)
Phase A trip on weak infeed
Phase B trip on weak infeed
Phase C trip on weak infeed
Power swing detected (3 single phase loop inside the
quad & crossing the ∆R band in less than 5ms in a 50
Hz network). Power swing is present either with out of
step cycle or stable swing cycle.
Current reversal guard logic in action
(Directional switching from Rev to Fwd in parallel line
application)
Programmable Logic
MiCOM 40 Agile P442, P444
Source
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance
PSL (OUT)
Distance

Advertisement

Table of Contents
loading

This manual is also suitable for:

P442P444

Table of Contents