GE MiCOM P40 Agile Technical Manual page 366

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

P44x/EN PL/Hb6
(PL) 6-46
Ordinal
English Text
778
LED 8 Red Condit
657
LED 9 Grn
656
LED 9 Red
656
LED Cond IN 1
657
LED Cond IN 2
658
LED Cond IN 3
659
LED Cond IN 4
660
LED Cond IN 5
661
LED Cond IN 6
662
LED Cond IN 7
663
LED Cond IN 8
1672 to
LN1 Analog Alarm to
1677
LN6 Analog Alarm
1688 to
LN1 Async to
1693
LN6 Async
1680 to
LN1 Test Mode to
1685
LN6 Test Mode
1704 to
LN1 Val Fail to
1709
LN6 Val Fail
1696 to
LN1 Val Quest to
1701
LN6 Val Quest
188
Lockout Alarm
331
Loss. Load Trip
191
Man CB Cls Fail
190
Man CB Trip Fail
192
Man CB Unhealthy
Description
Hardware version K - Assignment of signal to drive
output LED 8 red
Hardware version K - Programmable Green LED n° 9
Hardware version K - Programmable Red LED n° 9
Hardware version J - Assignment of signal to drive
output Function Key LED 1
Hardware version J - Assignment of signal to drive
output Function Key LED 2
Hardware version J - Assignment of signal to drive
output Function Key LED 3
Hardware version J - Assignment of signal to drive
output Function Key LED 4
Hardware version J - Assignment of signal to drive
output Function Key LED 5
Hardware version J - Assignment of signal to drive
output Function Key LED 6
Hardware version J - Assignment of signal to drive
output Function Key LED 6
Hardware version J - Assignment of signal to drive
output Function Key LED 7
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
If two consecutive of any Logical Node frames have
not been received within the Merge Unit Delay set
parameter (time of silence in the reception of the
frame), the LN is "absent"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
Any Logical Node is synchronized with Internal (local)
synchronization
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
Any Logical Node is in "Test Mode"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
The sample value (SV) transmitted status from the LN
is "failed"
Relays with IEC 61850 9-2 Ethernet board only
(software version D5.x)
The sample value (SV) transmitted status from the LN
is "questionable"
Lockout alarm: An alarm is issued with: 'Man CB
Unhealthy'or no 'Check Sync OK' (CB conditioning) or
'Man CB Cls Fail' or 'Man CB Fail Trip' or 'F.F. Lock' or
'CB Op Time Lock' or 'CB Ops Lockout'
Loss of load trip (in application without communication
scheme and a 3P Trip logic)
Alarm CB fail for manual closing command
Alarm CB Fail for manual trip command
Alarm CB performed by unhealthy condition
Programmable Logic
MiCOM 40 Agile P442, P444
Source
PSL
SW
SW
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL (OUT)
PSL (OUT)
Loss of load
PSL (OUT)
PSL (OUT)
PSL (OUT)

Advertisement

Table of Contents
loading

This manual is also suitable for:

P442P444

Table of Contents