Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 72

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Output instructions
■Out (excluding the timer, counter, and annunciator)
Instruction symbol
OUT
■Timer, long timer
Instruction symbol
OUT T
OUTH T
OUT ST
OUTH ST
OUT LT
OUT LST
■Counter, long counter
Instruction symbol
OUT C
OUT LC
■Annunciator
Instruction symbol
OUT F
■Setting devices (excluding annunciator)
Instruction symbol
SET
■Resetting devices (excluding annunciator)
Instruction symbol
RST
■Setting/resetting annunciator
Instruction symbol
SET F
RST F
■Rising/falling edge output
Instruction symbol
PLS
PLF
■Inverting the bit device output
Instruction symbol
FF
■Converting the direct access output into a pulse
Instruction symbol
DELTA
DELTAP
2 CPU MODULE INSTRUCTIONS
70
2.1 Sequence Instructions
Processing details
Outputs the operation result to the specified device.
Processing details
Starts time measurement when the operation result up to the OUT instruction is on. When time is
up, the normally open contact turns on (continuity state) and the normally closed contact turns off
(non-continuity state).
• OUT T: Low-speed timer instruction
• OUTH T: High-speed timer instruction
• OUT ST: Low-speed retentive timer instruction
• OUTH ST: High-speed retentive timer instruction
• OUT LT: Low-speed long timer instruction
• OUT LST: Low-speed long retentive timer instruction
Processing details
Increments the current counter value (count value) by one when the operation result up to the OUT
instruction turns on. When the count value reaches the set value, the normally open contact of the
counter turns on (continuity state) and the normally closed contact turns off (non-continuity state).
• OUT C: Counter
• OUT LC: Long counter
Processing details
Outputs the operation result up to the OUT F instruction to the specified annunciator.
Processing details
Turns on the specified bit.
Processing details
Turns off the specified device. For the timer and counter, the instruction clears the current value to
0 and turns off the contact or coil.
Processing details
Turns on the specified annunciator.
Turns off the specified annunciator.
Processing details
Turns on the specified device for one scan on the rising edge (off to on) of the execution command.
Turns on the specified device for one scan on the falling edge (on to off) of the execution
command.
Processing details
Inverts the status of the specified device.
Processing details
Converts the specified direct access output (DY) into pulse output.
Reference
Page 175 OUT
Reference
Page 177 OUT T,
OUTH T, OUT ST,
OUTH ST
Page 181 OUT LT,
OUT LST
Reference
Page 184 OUT C
Page 186 OUT LC
Reference
Page 188 OUT F
Reference
Page 189 SET
Reference
Page 191 RST
Reference
Page 193 SET F
Page 195 RST F
Reference
Page 197 PLS
Page 199 PLF
Reference
Page 201 FF
Reference
Page 203 DELTA(P)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents