Siemens SIPROTEC 4 User Manual page 629

Multi-functional protective relay with local control 7sj62/64
Hide thumbs Also See for SIPROTEC 4:
Table of Contents

Advertisement

Addr. Parameter
3107
VPH MAX
3108
64-1 VGND
3109
64-1 VGND
3110
64-1 VGND
3111
T-DELAY Pickup
3112
64-1 DELAY
3113
50Ns-2 PICKUP
3113
50Ns-2 PICKUP
3114
50Ns-2 DELAY
3115
67Ns-2 DIRECT
3117
50Ns-1 PICKUP
3117
50Ns-1 PICKUP
3118
50Ns-1 DELAY
3119
51Ns PICKUP
3119
51Ns PICKUP
3119
51Ns PICKUP
3120
51NsTIME DIAL
3120
51c TIME DIAL
3121A 50Ns T DROP-OUT
3122
67Ns-1 DIRECT.
3123
RELEASE DIRECT.
3123
RELEASE DIRECT.
3124
PHI CORRECTION
3125
MEAS. METHOD
3126
RESET DELAY
3127
51Ns I T min
3127
51Ns I T min
SIPROTEC 4, 7SJ62/64, Manual
C53000-G1140-C207-8, Edition 08.2016
Function
C
Setting Options
Sens. Gnd Fault
10 .. 100 V
Sens. Gnd Fault
1.8 .. 200.0 V; ∞
Sens. Gnd Fault
1.8 .. 170.0 V; ∞
Sens. Gnd Fault
10.0 .. 225.0 V; ∞
Sens. Gnd Fault
0.00 .. 320.00 sec;
Sens. Gnd Fault
0.10 ..
40000.00 sec; ∞
Sens. Gnd Fault
0.001 .. 1.500 A
Sens. Gnd Fault 1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Sens. Gnd Fault
0.00 .. 320.00 sec;
Sens. Gnd Fault
Forward
Reverse
Non-Directional
Sens. Gnd Fault
0.001 .. 1.500 A
Sens. Gnd Fault 1A
0.05 .. 35.00 A
5A
0.25 .. 175.00 A
Sens. Gnd Fault
0.00 .. 320.00 sec;
Sens. Gnd Fault
0.001 .. 1.400 A
Sens. Gnd Fault
0.003 .. 0.500 A
Sens. Gnd Fault 1A
0.05 .. 4.00 A
5A
0.25 .. 20.00 A
Sens. Gnd Fault
0.05 .. 4.00 sec; ∞
Sens. Gnd Fault
0.50 .. 15.00 ; ∞
Sens. Gnd Fault
0.00 .. 60.00 sec
Sens. Gnd Fault
Forward
Reverse
Non-Directional
Sens. Gnd Fault
0.001 .. 1.200 A
Sens. Gnd Fault 1A
0.05 .. 30.00 A
5A
0.25 .. 150.00 A
Sens. Gnd Fault
-45.0 .. 45.0 °
Sens. Gnd Fault
COS φ
SIN φ
Sens. Gnd Fault
0 .. 60 sec
Sens. Gnd Fault
0.003 .. 1.400 A
Sens. Gnd Fault 1A
0.05 .. 20.00 A
5A
0.25 .. 100.00 A
Functions, Settings, Information
Default Setting
Comments
75 V
L-Gnd Voltage of
Unfaulted Phase Vph Max
40.0 V
64-1 Ground Displace-
ment Voltage
40.0 V
64-1 Ground Displace-
ment Voltage
70.0 V
64-1 Ground Displace-
ment Voltage
1.00 sec
Time-DELAY Pickup
10.00 sec
64-1 Time Delay
0.300 A
50Ns-2 Pickup
10.00 A
50Ns-2 Pickup
50.00 A
1.00 sec
50Ns-2 Time Delay
Forward
67Ns-2 Direction
0.100 A
50Ns-1 Pickup
2.00 A
50Ns-1 Pickup
10.00 A
2.00 sec
50Ns-1 Time delay
0.100 A
51Ns Pickup
0.004 A
51Ns Pickup
1.00 A
51Ns Pickup
5.00 A
1.00 sec
51Ns Time Dial
5.00
51c Time dial
0.00 sec
50Ns Drop-Out Time
Delay
Forward
67Ns-1 Direction
0.010 A
Release directional
element
0.50 A
Release directional
element
2.50 A
0.0 °
Correction Angle for Dir.
Determination
COS φ
Measurement method for
Direction
1 sec
Reset Delay
1.333 A
51Ns Current at const.
Time Delay T min
15.00 A
51Ns Current at const.
Time Delay T min
75.00 A
F.2 Settings
629

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents