Siemens SIPROTEC 4 User Manual page 535

Multi-functional protective relay with local control 7sj62/64
Hide thumbs Also See for SIPROTEC 4:
Table of Contents

Advertisement

Functions
DGFD
motor
Dir
DGFD
motor
Dir
IEF
motor
Dir
motor
DGFD = Directional ground fault detection
IEF = Intermittent ground (earth) fault protection
Dir = Directional Time Overcurrent Protection (67 and 67N Elements)
V, f, P = Voltage protection, frequency protection, power protection
1)
for isolated/compensated networks, only for sensitive ground current transformer if 7th digit = 2, 6
2)
only for non-sensitive ground current transformer if 7th digit = 1, 5, 7
Automatic Reclosing (79) / Fault Locator / Synchronization
SIPROTEC 4, 7SJ62/64, Manual
C53000-G1140-C207-8, Edition 08.2016
V, f, P 67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
QU protection
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
V, f, P 67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
Intermittent ground fault
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
QU protection
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
V, f, P 67/67N
Directional overcurrent protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
QU protection
27/47/59(N)/
Flexible protection functions (parameters from current
32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
48/14
Motor starting protection, locked rotor
66/86
Reclosing lockout
51M
Load jam protection in motors, motor statistics
Without
Ordering Information and Accessories
A.2 Ordering Information 7SJ64 V4.9
Pos. 14
and 15
H H
R H
H G
H A
Pos. 16
0
1)
1)
535

Hide quick links:

Advertisement

Table of Contents
loading