SIPROTEC 4, 7SJ62/64, Manual
C53000-G1140-C207-8, Edition 08.2016
67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
V, f, P 67Ns
Sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault protection
27/59
High-impedance ground fault protection
81U/O
Under/Overfrequency
QU protection
27/47/59(N)
Flexible protection functions (parameters from current
/32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
Intermittent ground fault
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
V, f, P 67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
QU protection
27/47/59(N)
Flexible protection functions (parameters from current
/32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
V, f, P 67/67N
Directional overcurrent protection
67Ns
Directional sensitive ground fault detection
67Ns
Directional detection of intermittent ground faults
87N
High-impedance ground fault differential protection
48/14
Motor starting protection, locked rotor
66/86
Restart inhibit for motors
51M
Load jam protection in motors, motor statistics
27/59
Under/Overvoltage 59-1, 59-2, 27-1, 27-2
81O/U
Under/Overfrequency
QU protection
27/47/59(N)
Flexible protection functions (parameters from current
/32/55/81R
and voltage): Voltage/power/power factor/frequency
change/voltage change protection
Ordering Information and Accessories
A.1 Ordering Information 7SJ62 V4.9
Pos. 14
and 15
F D
F F
1)
P D
F B
1)
H F
H H
1)
1)
1)
1)
529