Introduction
The MCM-400 HFR has two different IR addresses:
Common address.
Device address;
The Common address is typically used to address multiple MCM-400 HFRs at once or to address the device at its very first use. By
default, the common address is set to 0, but it can be set to 1 as well to avoid interaction with other non-Barco devices, programmed
to the same IR address.
The Device address is used to address one MCM-400 HFR at a time. This address can be set in the range 0..255 (default is 1). It
must be taken into account however that a standard RCU can only communicate with devices having their address set in the range
0..9.
The MCM-400 HFR address and the RCU address must be set to the same value to allow communication.
Setting the MCM-400 HFR address
1. In the OSD, navigate to Installation > IR address... and press ENTER to select.
Image 6-6
2. In the addresses dialog box, fill out the desired value for the addresses.
-
Device address.
-
Common RC5 address
Image 6-7
3. Exit the menu.