10.3.5 Color calibration

C
AUTION
Description
In a multiple channel setup, it might be needed to match the colors amongst all display channels. If the colors are nearly matched
amongst the channels, try using the color fine tuning procedure to fully match them.
If not successful, it might be required to measure the native colors of the display per channel and enter them as measured values in
the according MCM-400 HFR. This is color calibration. After that, the color coordinates for a common color triangle can be calculated.
Necessary tools
Spectrometer
Calibrating the colors of a display channel
1. Check to see which Dynacolor set is currently active: Display setup > Dynacolor > Active set: the set that has the radio button
is the active set.
2. In the OSD, navigate to the active Dynacolor set: Display setup > Dynacolor > Adjust Set 1... or Adjust Set 2... and press ENTER
to select.
Image 10-66
3. In the Dynacolor Set dialog box, click Calibration.
A red full screen test pattern is displayed.
4. Use a spectrometer to measure the exact x and y value and brightness of the displayed color and press ENTER to proceed.
5. In the Calibration dialog box , fill in the measured x and y coordinates and the Y (i.e. brightness) value.
R5909056 MCM-400 HFR 11/05/2016
:
Color calibration may only be done by Barco trained and qualified engineers.