Firmware Upgrade - Barco MCM-400 HFR User Manual

Table of Contents

Advertisement

11. Maintenance

11.3 Firmware upgrade

Upgrade tool
The name of the upgrade tool is according to this format:
Two main parts can be seen:
device: this is the device type
-
MCM-400 HFR
version: indicates the version
-
two first digit (e.g. 01): major revision;
-
second pair of digits (e.g. 20): minor revision;
-
last four digits (e.g. 0005): build number.
Necessary tools
Ethernet connection to the MCM-400 HFR
Upgrading the firmware
1. Download the latest MCM-400 HFR software version from My.barco.com (https://my.barco.com).
2. Save this upgrade file on a computer which is connected to the same (local) network as the MCM-400 HFR.
3. Make sure that the MCM-400 HFR is powered.
4. On the computer, double click the upgrade tool.
5. Enter the IP address or hostname of the MCM-400 HFR and click OK.
Image 11-1
Upgrading device
6. Carefully follow the instructions to proceed.
7. During the upload of the upgrade files to the device, a progress bar is displayed.
Caution:
Do not switch off the MCM-400 HFR, nor the computer during the upgrade procedure!
Note: In case of problems during the upgrade procedure, the following two buttons can be used for diagnostics reasons:
Save text will save the text inside the Barco Networked Projector Upgrade Tool in a file;
Screen shot will save a screen shot of the displayed screen at that particular time.
8. When the upgrade is successful, a green ellipse appears at the bottom of the window and an information window pops up.
9. Click OK to finish the upgrade.
10.Reboot the MCM-400 HFR external warp box by doing the following:
a) Switch the MCM-400 HFR to standby;
b) Unplug the power supply;
c) Plug in the power supply.
If the upgrade fails, a red ellipse appears at the bottom of the window and a message pops up. Restart the
procedure.
On startup of the MCM-400 HFR after an upgrade of its software, the controller checks the software of the
different boards and modules in the MCM-400 HFR. If an old software version in one of these parts is detected,
it is replaced by the new version. During this upgrading sequence, power may be switched automatically!
162