Introduction
As soon as the AC mains power adapter is connected to both the MCM-400 HFR unit and the wall outlet, the MCM-400 HFR starts
configuring and goes to active state. If the MCM-400 HFR is part of a full display system - which will be the case - a specified
power-on sequence must be followed to allow EDID communication.
Powering the MCM-400 HFR
Connect the power supply to both the MCM-400 HFR and the wall outlet.
Power-on sequence
1. Network switch (if present); allows IP address assignment to MCM-400 HFR in case of a DHCP/DNS network;
2. Projector connected with the MCM-400 HFR. (Galaxy 4K HFR or HDQ-4K40 series projector).
3. MCM-400 HFR;
4. Sources; the sources can now read the EDID data on the MCM-400 HFR inputs.