10. Expert operation

10.1.4 Transport delay

Description
Transport delay is the time interval that is required to fully process the image.
Transport delay can be set to Automatic or to Manual. Default is Automatic.
Automatic: the projector takes the minimum safe value, required to fully perform the image processing.
Manual: the delay can be changed in the range 0 to 1023, expressed in line duration of the lock source.
Advised use of Transport delay
In a single channel display system, you can leave the Transport delay setting to Automatic.
In multiple channel display systems, it is strongly advised to follow this sequence:
1.
Make sure that the Transport delay of all projectors is set to Automatic.
2.
Adjust the geometry until it is well aligned in all devices.
3.
Check the Transport delay value in all devices and find the highest value.
4.
Switch Transport delay to Manual in all projectors.
5.
Enter the highest value that was found as new Transport delay value in all devices.
A Transport delay set too short will introduce 'clipping' phenomenons in the image.
Adjusting the Transport delay
1. In the OSD, navigate to Geometry > Edit > Transport Delay... and press ENTER to select.
Image 10-22
The Transport delay dialog box is displayed.
Image 10-23
2. Select the desired option: Automatic or Manual.
If the option Manual is selected, then the TDR value text box is enabled. To set the TDR value see the procedure below.