Configuration Procedure - HPE FlexNetwork HSR6800 series Configuration Manual

High availability configuration guide
Hide thumbs Also See for FlexNetwork HSR6800 series:
Table of Contents

Advertisement

Configuration procedure

To configure BFD basic functions:
Step
1.
Enter system view.
2.
Specify the mode for
establishing a BFD session.
3.
Configure the destination
port number for multi-hop
BFD control packets.
4.
Configure the source IP
address of echo packets.
5.
Enter interface view.
6.
Configure the minimum
interval for receiving BFD
echo packets.
7.
Configure the minimum
interval for transmitting BFD
control packets.
8.
Configure the minimum
interval for receiving BFD
control packets.
9.
Configure the detection time
multiplier.
In
Figure
52, if you configure the Desired Min TX Interval as 100 milliseconds, Required Min RX
Interval as 300 milliseconds, and Detect Mult as 5 on Router A, and then configure the Desired Min
TX Interval as 150 milliseconds, Required Min RX Interval as 400 milliseconds, and Detect Mult as
10 on Router B:
Command
system-view
bfd session init-mode { active |
passive }
bfd multi-hop destination-port
port-number
bfd echo-source-ip ip-address
interface interface-type
interface-number
bfd min-echo-receive-interval
value
bfd min-transmit-interval value
bfd min-receive-interval value
bfd detect-multiplier value
199
Remarks
N/A
Optional.
active by default.
Optional.
4784 by default.
Optional.
The source IP address should not
be on the same network segment
as any local interface's IP
address. Otherwise, a large
number of ICMP redirect packets
might be sent from the peer,
resulting in link congestion.
N/A
Optional.
For more information, see the
description of the Required Min
Echo RX Interval field in
packet
format."
The default setting is 400
milliseconds.
Optional.
For more information, see the
description of the Desired Min TX
Interval field in
"BFD packet
format."
The default setting is 400
milliseconds.
Optional.
For more information, see the
description of the Required Min
RX Interval field in
"BFD packet
format."
The default setting is 400
milliseconds.
Optional.
For more information, see the
description of the Detect Mult field
in
"BFD packet
format."
5 by default.