Configuring Link Monitoring; Configuring Errored Symbol Event Detection; Configuring Errored Frame Event Detection; Configuring Errored Frame Period Event Detection - HPE FlexNetwork HSR6800 series Configuration Manual

High availability configuration guide
Hide thumbs Also See for FlexNetwork HSR6800 series:
Table of Contents

Advertisement

Configuring link monitoring

After Ethernet OAM connections are established, the link monitoring periods and thresholds
configured in this section automatically take effect on all Ethernet ports.

Configuring errored symbol event detection

An errored symbol event occurs when the number of detected symbol errors during a specific
detection interval exceeds the predefined threshold.
To configure errored symbol event detection:
Step
1.
Enter system view.
2.
Configure the errored
symbol event
detection interval.
3.
Configure the errored
symbol event
triggering threshold.

Configuring errored frame event detection

An errored frame event occurs when the number of detected error frames during a specific interval
exceeds the predefined threshold.
To configure errored frame event detection:
Step
1.
Enter system view.
2.
Configure the errored
frame event detection
interval.
3.
Configure the errored
frame event triggering
threshold.

Configuring errored frame period event detection

An errored frame period event occurs if the number of frame errors in a specific number of received
frames exceeds the predefined threshold.
To configure errored frame period event detection:
Step
1.
Enter system view.
2.
Configure the errored frame
period event detection period.
3.
Configure the errored frame
period event triggering
threshold.
Command
system-view
oam errored-symbol period
period-value
oam errored-symbol threshold
threshold-value
Command
system-view
oam errored-frame period period-value
oam errored-frame threshold
threshold-value
Command
system-view
oam errored-frame-period
period period-value
oam errored-frame-period
threshold threshold-value
12
Remarks
N/A
Optional.
1 second by default.
Optional.
1 by default.
Remarks
N/A
Optional.
1 second by default.
Optional.
1 by default.
Remarks
N/A
Optional.
1000 milliseconds by default.
Optional.
1 by default.

Advertisement

Table of Contents
loading

Table of Contents