HPE FlexNetwork HSR6800 series Configuration Manual page 24

High availability configuration guide
Hide thumbs Also See for FlexNetwork HSR6800 series:
Table of Contents

Advertisement

Port
: GigabitEthernet3/0/1
Link Status : Up
Event statistic :
-------------------------------------------------------------------------
Link Fault
:0
The output shows that no critical link event occurred on the link between Router A and Router
B.
You can use the display oam link-event command to display the statistics of Ethernet OAM
link error events. For example:
# Display Ethernet OAM link event statistics of the remote end of Router B.
[RouterB] display oam link-event remote
Port :GigabitEthernet3/0/1
Link Status :Up
OAMRemoteErrFrameEvent : (ms = milliseconds)
---------------------------------------------------------------------
Event Time Stamp
Errored Frame Threshold
Error Running Total
The output shows that 35 errors occurred since Ethernet OAM was enabled on Router A, 17 of
which were caused by error frames. The link is unstable.
Dying Gasp
: 0
: 5789
: 1
: 35
17
Critical Event
Errored Frame Window
Errored Frame
Event Running Total
: 0
: 10(100ms)
: 3
: 17

Advertisement