How Software Handles Monitored Entrapment; Table 4: Changes To Sensor Inputs On The Controller - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

H
S
ow
oftware
Since HySecurity gate operators use software to control gate movement, contacts, and accessories, the changeover to
monitored sensors is simple. In fact, the ability to monitor sensors has always been an available Installer Menu item. (Refer
to Table 6: Setting the Sensor Logic on page 11) Instead of an option, it now becomes the default standard.
Build Year is a new Installer Menu item in Smart DC and Smart Touch Controllers versions h5.50 and h4.50 (and
higher).
New labels show where Edge, Photo Eye Open and Photo Eye Closed have changed to "SENSOR" inputs. You
can program the type of sensor wired to one of those inputs. Refer to illustrations on page 7 and Table 4
below.
Installer Menu items, PC and GC (Photo eye output and edge sensor output) which used to default to Normally
Open (NO) have been converted to Normally Closed (NC) contacts so the software can detect the presence and
proper operation of entrapment protection sensors.

Table 4: Changes to Sensor Inputs on the Controller

Location of Sensor Inputs on Controller
Smart Touch Controller (STC): Hydraulic gate operators
Input #
Current Silk Screen Label
13
EDGE SENSOR
17
PHOTO EYE OPEN DIRECTION
19
PHOTO EYE CLOSE DIRECTION
Smart DC Controller (SDC):
Electromechanical gate operators
No numerical input
EYE OPEN
number appears on
EYE CLOSE
Smart DC
EDGE
NOTE: Three inputs for external entrapment protection sensors are available on the HySecurity gate operator controller. New silk
screen controller boards are on order, but until they are ready for shipment, labels will be overlaid on the board to indicate
terminology adaptations.
Table 4 indicates how the edge and photo eye inputs have been renamed to generic "sensor" inputs. They are
interchangeable and configurable. The software must know what type of sensor is wired to SENSOR 1, 2, and 3 BEFORE it
will allow gate travel. Refer to page 10.
8
D0726 Rev. J
H
m
andLeS
onItored
2016 Silk Screen
SENSOR 1
SENSOR 2
SENSOR 3
SENSOR 2
SENSOR 3
SENSOR 1
UL 325 - 2016 HySecurity Monitored Sensors
e
ntrapment
Installer Menu Item Codes
OLED - two line,
Label
32 character
S1 SENSOR 1
S2 SENSOR 2
S3 SENSOR 3
S2 SENSOR 2
S3 SENSOR 3
S1 SENSOR 1
Smart Touch Display:
LCD - 7
segment text
S1
S2
S3
Smart DC Display:
32 character LCD
© 2016 www.hysecurity.com