Important Considerations for DC-powered Operators

Installing the Extended Battery Backup Kit

Post-mounted
operator with
base extension
HySecurity offers an extended DC power back up option with two 50Ah batteries. Contact HySecurity parts
department to order extended battery backup kit with base extension (P/N MX002141).
To install the extended battery backup kit:
1. Turn off the DC and AC power switches.
2. Place the accessory tray on the studs inside the
base riser. See Figure 2-10.
3. To access the 8Ah batteries and disconnect its
wires, cut the two black wire ties and slide the
8Ah batteries through the access window.
Another option is to remove the four screws
that hold the control box to the chassis. See
Figure 2-9.
DANGER
!
Make sure both the left and right 8Ah DC battery wires are disconnected. Never mix battery sizes,
types, or brands. HySecurity strongly recommends that only sealed AGM style batteries be used.
If you plan to remove the batteries from the operator, properly store or discard them. Refer to
Hazardous Materials and Proper
2-12
Posts not included
in kit
Disposal.
SlideSmart DC Installation and Reference Manual
Figure 2-8.
8Ah battery
Screws
(4x)
Control box
50Ah batteries
Accessory tray
Access window
Wire ties
Figure 2-9.