The following bullet points highlight how your automated gate system sites can monitor external entrapment protection
using HySecurity gate operators:
• Normally Closed (NC) sensors - Before gate movement occurs, the gate operator verifies that the external entrapment protection
sensor is connected and fully functional.
• Build Year (BY) - An added menu item distinguishes between pre-2016 manufacturing dates and post-2016 manufacturing dates.
Build Year (BY) is a factory-setting. Build Year 2 (BY 2) is the default for all HySecurity gate operators indicating a manufacturing date
of 2016 in the serial number. Replacement controller boards for existing sites allow for a Build Year setting of 1 (BY 1) (pre-2016).
• Independent Sensor Inputs - The edge, photo eye and photo eye COM inputs on the Smart Touch and Smart DC Controllers (STC
and SDC) have been re-labeled. The same wiring connections become three independent methods for easy entrapment sensor
configuration and normally closed outputs. Refer to page 7.
Table 1: HySecurity Gate Operators requiring External Monitored Entrapment
Protection Sensors

HySecurity Gate Operators

(includes Modular, Correctional, and UPS
models)
SlideDriver 15, 40, 30F, 50VF 2/3, 80, 200
SlideDriver 50VF series
SlideSmart DC 15 & DCS 15
SlideSmart DC 10F & DCS 10F
SwingRiser 14, 14-Twin, 19,
19-Twin, 30, 30-Twin
SwingSmart DC 20 & DCS 20
HydraSwing 40, 40F, 40-Twin, 40F-Twin,
80F, 150
HydraLift 10, 10F, 20, 20F
*NOTE: Refer to tables on 6 and 10.
Table 2: HySecurity Gate Operators maintaining Object Detection
Table 2 indicates those HySecurity gate operators that may be within the exception parameters of UL 325 or comply with
standards other than UL 325, but continue to maintain object detection capabilities. HySecurity strongly recommends that
you assess every site for entrapment zones and provide the necessary protection to guard against entrapment.
HySecurity Gate Operators
with
Obstruction Protection (Object Detection)
StrongArm (HTG) 14, 20, 28, 36
StrongArmCRASH (M30/M50)
StrongArmPark DC 10 & DCS 10
StrongArmPark DC 14 & DCS 14
WedgeSmart DC 10 & 10 DCS
WedgeSmart DC 14 & 14 DCS
HydraWedge SM50 with HydraSupply XL
www.hysecurity.com © 2016
G
o
ate
peratorS
Build Year
post-2016
(set at the factory)
2
2
2
2
2
2
2
2
Build Year
post-2016
UL 325 Entrapment Protection Device Monitoring Required
Normally Closed (NC) sensors tested & approved.*
Three SENSOR Inputs on Controller.
Installer Menu configurable.*
Build Year (BY) factory-set to post-2016.
Sensor Inputs automatically set to "NOT USED"
Installer has option to change settings as site design dictates.