Dxi6900 Environmental Specifications - Quantum DXi6900 User Manual

With dxi 3.2.5 software
Hide thumbs Also See for DXi6900:
Table of Contents

Advertisement

Chapter 11: System Specifications

DXi6900 Environmental Specifications

Average AC Current
Inrush Peak AC Current

DXi6900 Environmental Specifications

DXi6900 Environmental Specifications
DXi6900 Climatic Environment
Temperature
Operating
Shipping and storage
Relative humidity
Operating
Shipping and storage
Altitude
Operating
Shipping and storage
DXi6900 Vibration and Shock
Quantum DXi6900 User's Guide
Node
Array Module (RBOD)
Expansion Module (EBOD)
Maximum Configuration
10° to 35°C (50° to 95°F) with a maximum temperature gradient of
10°C per hour
Note: 35°C (95°F) is the maximum temperature for the
DXi6900 at sea level. For every 1,000 feet (305 meters) of
altitude, the maximum temperature is reduced by 0.9°C.
–20° to 60°C (4° to 140°F) with a maximum temperature gradient
of 20°C per hour
20% to 80% (non-condensing) with a maximum humidity gradient
of 10% per hour
5% to 95% (non-condensing) with a maximum humidity gradient
of 10% per hour
–16m to 3048 m (–50 to 10,000 ft)
–16m to 10,600 m (–100 to 35,000 ft)
468 Watts, 4.7A @100 VAC 1597 BTU/hr
468 Watts, 1.9A @240 VAC 1597 BTU/hr
276 Watts, 2.8A @100 VAC 942 BTU/hr
276 Watts, 1.2A @240 VAC 942 BTU/hr
168 Watts, 1.8A @100 VAC 780 573 BTU/hr
168 Watts, 0.8A @240 VAC 780 573 BTU/hr
59A @ 100 VAC 25A @ 240 VAC