Operating Conditions: Process; 10.1.10 Mechanical Construction - Endress+Hauser Proline Prosonic Flow 93T Portable Operating Instructions Manual

Portable ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 93T Portable:
Table of Contents

Advertisement

Technical data
Medium temperature range
Medium pressure range
(nominal pressure)
Pressure loss
Design / dimensions
Weight
!
62
10.1.9

Operating conditions: process

Prosonic Flow P sensor
DN 15 to 65 (½ to 2½")
• Standard: –40 to +100 °C (–40 to +212 °F)
• Optional: –40 to +150 °C (–40 to +302 °F)
DN 50 to 4000 (2 to 160")
• Standard: –40 to +80 °C (–40 to +176 °F)
• Optional: 0 to +170 °C (+32 to +338 °F)
DDU18 sensor (accessories: sound velocity measurement)
• Standard: –40 to +80 °C (–40 to +176 °F)
• Optional: 0 to +170 °C (+32 to +338 °F)
DDU20 sensor (accessories: wall thickness measurement)
–10 to +60 °C (+14 to +140 °F)
No pressure limitation, however perfect measurement requires that the static fluid pressure is higher
than vapor pressure.
There is no pressure loss.

10.1.10 Mechanical construction

The dimensions and lengths of the sensor and transmitter are provided in the separate "Technical
Information" document on the device in question. This can be downloaded as a PDF file from
www.endress.com.
A list of the "Technical Information" documents available is provided on  ä 64.
Transmitter
1.6 kg (3.53 lbs)
Sensor Prosonic Flow P
• DN 15 to 65 (½ to 2½") (incl. mounting material):
• DN 50 to 4000 (2 to 160") (incl. mounting material): 2.8 kg (6.2 lbs)
Sensor (accessories)
• Prosonic Flow DDU18 (incl. mounting material): 2.4 kg (5.3 lbs)
• Prosonic Flow DDU20 (incl. mounting material): 0.23 kg (0.5 lbs)
Note!
Weight information without packaging material.
Proline Prosonic Flow 93T Portable
1.78 kg (3.9 lbs)
Endress+Hauser

Hide quick links:

Advertisement

Table of Contents
loading