Operation; Quick Operation Guide; Display And Operating Elements - Endress+Hauser Proline Prosonic Flow 93T Portable Operating Instructions Manual

Portable ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 93T Portable:
Table of Contents

Advertisement

Proline Prosonic Flow 93T Portable
Endress+Hauser
5

Operation

5.1

Quick operation guide

You have a number of options for configuring and commissioning the device:
Local display (option)  ä 33
1.
The local display enables you to read all of the important parameters directly at the measuring
point, configure device-specific parameters in the field and commission the instrument.
Configuration program  ä 39
2.
You can commission the device with the FieldCare operating program.
5.2

Display and operating elements

The local display enables you to read all important parameters directly at the measuring point and
configure the device using the "Quick Setup" or the function matrix.
The display area consists of four lines; this is where measured values are displayed, and/or status
variables (direction of flow, bar graph, etc.). You can change the assignment of display lines to
different variables to suit your needs and preferences.
1
2
Fig. 37:
Display and operating elements
Liquid crystal display (1)
The backlit, four-line liquid-crystal display shows measured values, dialog texts, error messages and notice
messages. The display as it appears when normal measuring is in progress is known as the HOME position
(operating mode).
Optical sensors for "Touch Control" (2)
2
Plus/minus keys (3)
– HOME position  Direct access to totalizer values and actual values of inputs/outputs
– Enter numerical values, select parameters
– Select different blocks, groups and function groups within the function matrix
Press the OS keys simultaneously to trigger the following functions:
– Exit the function matrix step by step  HOME position
– Press and hold down the OS keys for longer than 3 seconds  Return directly to HOME position
– Cancel data entry
3
Enter key (4)
– HOME position  Entry into the function matrix
– Save the numerical values you input or settings you change
+24.502
+24.502
v
v
S
S
+1863.97
+1863.97
3
3
v
v
–50
–50
+50
+50
Esc
-
+
3
Operation
x
x
y
y
x
x
y
y
%
%
E
4
A0001172
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents