Summary of Contents for Endress+Hauser Proline Prosonic Flow B 200
Page 1
Brief Operating Instructions Proline Prosonic Flow B 200 Ultrasonic flow measuring system These Instructions are Brief Operating Instructions; they do not replace the Operating Instructions included in the scope of supply. For detailed information, refer to the Operating Instructions and other documentation on the CD-ROM provided or visit "www.endress.com/...
Proline Prosonic Flow B 200 Document conventions Document conventions Document conventions 1.1.1 Safety symbols Symbol Meaning DANGER! DANGER This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. A0011189-EN WARNING! WARNING This symbol alerts you to a dangerous situation.
Page 4
Document conventions Proline Prosonic Flow B 200 1.1.4 Symbols for certain types of information Symbol Meaning Allowed Indicates procedures, processes or actions that are allowed. A0011182 Preferred Indicates procedures, processes or actions that are preferred. A0011183 Forbidden Indicates procedures, processes or actions that are forbidden.
Proline Prosonic Flow B 200 Basic safety instructions Basic safety instructions Requirements for the personnel The personnel must fulfill the following requirements for its tasks: Trained, qualified specialists must have a relevant qualification for this specific function and ► task Are authorized by the plant owner/operator ►...
It fulfills general safety requirements and legal requirements. It also conforms to the EC directives listed in the device-specific EC declaration of conformity. Endress+Hauser confirms this fact by applying the CE mark. Endress+Hauser...
Proline Prosonic Flow B 200 Incoming acceptance and product identification A0015502 A0013697 If one of the conditions does not comply, contact your Endress+Hauser distributor. Product identification The following options are available for identification of the measuring device: • Nameplate specifications •...
Storage and transport Proline Prosonic Flow B 200 Storage and transport Storage conditions Observe the following notes for storage: • Store in original packaging. • Do not remove protective covers or protective caps installed on process connections. • Protect from direct sunlight.
Page 11
Proline Prosonic Flow B 200 Storage and transport A0015604 A0015605 Endress+Hauser...
Mounting Proline Prosonic Flow B 200 Mounting Mounting requirements No special measures such as supports are necessary. External forces are absorbed by the construction of the device. 6.1.1 Mounting position Mounting location A0015543 Orientation The direction of the arrow on the sensor helps you to install the sensor according to the flow direction.
Page 13
Proline Prosonic Flow B 200 Mounting A0015895 Orientation Compact version Vertical orientation A0015545 Horizontal orientation, transmitter head up * A0015589 Horizontal orientation, transmitter head down * A0015590 Horizontal orientation, transmitter head at side A0015592 * A maximum deviation of only ±3 ° is permitted for the horizontal alignment of the transducers.
Mounting Proline Prosonic Flow B 200 convection errors during temperature measurement. A further factor which can lead to measurement errors due to heat convection is a low flow velocity. Mounting the measuring device 6.2.1 Required tools For transmitter • For turning the transmitter housing: Open-ended wrench 8 mm (0.31 in) •...
Proline Prosonic Flow B 200 Mounting max. 350° 8 mm 8 mm A0013713 6.2.5 Turning the display module 3 mm A0013905 Post-mounting check Is the device undamaged (visual inspection)? Does the measuring device conform to the measuring point specifications? For example: •...
Page 18
Mounting Proline Prosonic Flow B 200 Are the measuring point identification and labeling correct (visual inspection)? Is the device adequately protected from precipitation and direct sunlight? Are the securing screw and securing clamp tightened securely? Endress+Hauser...
Proline Prosonic Flow B 200 Electrical connection Electrical connection Connection conditions 7.1.1 Required tools • For cable entries: Use corresponding tools • For securing clamp: Allen key M3 • Wire stripper • When using stranded cables: Crimping tool for wire end ferrule •...
Electrical connection Proline Prosonic Flow B 200 2-wire / Flow Spare part 71108602 HART [04/05] A0013703 å 5 Example of a nameplate on the I/O electronic module Information on the outputs and their terminal assignment 7.1.5 Preparing the measuring device 1.
Page 21
Proline Prosonic Flow B 200 Electrical connection 7.2.1 Connecting the signal cables 3 mm 20 mm 10 (0.4) mm (in) A0013836 For HART communication: When connecting the cable shielding to the ground terminal, observe the grounding concept of the facility.
Electrical connection Proline Prosonic Flow B 200 Special connection instructions 7.3.1 Connection examples Ensuring the degree of protection The measuring device fulfills all the requirements for the IP66 and IP67 (Type 4X enclosure) degree of protection. To guarantee IP 66 and IP 67 degree of protection (Type 4X enclosure), carry out the following steps after the electrical connection: 1.
Proline Prosonic Flow B 200 options options Structure and function of the operating menu 8.1.1 Structure of the operating menu A0014058-EN 8.1.2 Operating philosophy The individual parts of the operating menu are assigned to certain user roles. Each user role corresponds to typical tasks within the device lifecycle.
Proline Prosonic Flow B 200 Access to the operating menu via the local display A0014013 Operational display with measured value shown as "1 value, max." (example) 1.1 Device tag 1.2 Display area for measured values (4-line) 1.3 Explanatory symbols for the measured value: measured value type, measuring channel number, symbol for event behavior 1.4 Status area...
Page 25
Proline Prosonic Flow B 200 options 8.2.1 Operational display Status area Status signals A0013956 A0013959 A0013958 A0013957 Failure Function check Out of specification Maintenance required Diagnostic behavior Locking Communication A0013961 A0013962 A0013965 A0013963 Alarm Warning Device locked Remote operation enabled...
Page 26
Proline Prosonic Flow B 200 8.2.2 Navigation view Status area The following appears in the status area of the navigation view in the top right corner: • Of the submenu – The direct access code for the parameter you are navigating to (e.g. 0022-1) –...
Page 27
Proline Prosonic Flow B 200 options Correction symbols under A0013990 A0013991 A0013989 A0013988 Clears all entered characters. Moves the input position one Moves the input position one Deletes one character position to the left. position to the right. immediately to the left of the input position.
Page 28
Proline Prosonic Flow B 200 Meaning Escape key combination (press keys simultaneously) In a menu, submenu • Pressing the key briefly: – Exits the current menu level and takes you to the next higher level. – If help text is open, closes the help text of the parameter.
Page 29
Proline Prosonic Flow B 200 options 8.2.6 User roles and related access authorization The two user roles "Operator" and "Maintenance" have different write access to the parameters if the customer defines a user-specific access code. This protects the device configuration via the local display from unauthorized access (®...
Proline Prosonic Flow B 200 A0016215-EN Access to the operating menu via the operating tool For detailed information about access to the operating menu via operating tool, refer to the Operating Instructions for the device on the CD-ROM provided 8.3.1...
Proline Prosonic Flow B 200 Commissioning Commissioning Function check Before commissioning the device, make sure that the post-installation and post-connection checks have been performed. • "Post-mounting check" checklist (® ä 17) • "Post-connection check" checklist (® ä 22) Switching on the measuring device After a successful function check, switch on the measuring device.
Commissioning Proline Prosonic Flow B 200 X X X X X X X 20.50 Main menu 0104-1 Language English Display/operat. Setup Language 0104-1 English à Deutsch Español Français Language 0104-1 à English Deutsch Español Français Hauptmenü 0104-1 Sprache Deutsch Anzeige/Betrieb...
Proline Prosonic Flow B 200 Commissioning Navigation path Setup ® Advanced setup ® Device tag User entry Max. 32 characters, such as letters, numbers or special characters (e.g. @, %, /) In the factory configuration, the tag name appears at the top left in the header.
Diagnostic information Proline Prosonic Flow B 200 XXXXXXXXXXXXX 3 mm A0013768 1. Loosen the securing clamp. 2. Unscrew the electronics compartment cover. 3. Pull out the display module with a gentle rotational movement. 4. To make it easier to access the lock switch, attach the display module to the edge of the electronics compartment.
Page 35
Proline Prosonic Flow B 200 Diagnostic information X X X X X X X X X X X X X X 20.50 S441 Curr. output 1 Curr. output 1 (ID:153) S441 2d11h05m55s 1. Check process 2. Check current output settings A0013940-EN å...
Need help?
Do you have a question about the Proline Prosonic Flow B 200 and is the answer not in the manual?
Questions and answers