Operating Conditions: Process - Endress+Hauser Proline t-mass 65 Operating Instructions Manual

Thermal mass flow measuring system
Hide thumbs Also See for Proline t-mass 65:
Table of Contents

Advertisement

Technical data
Medium temperature range
Medium pressure range
(nominal pressure)
Limiting flow
Pressure loss
Medium pressure
88
10.1.9

Operating conditions: Process

Sensor:
t-mass F:
–40 °C...+100 °C (–40 °F to +212 °F)
t-mass I:
–40 °C...+130 °C (–40 °F to +266 °F)
Seals:
t-mass F:
Viton –20°C...+100°C (–4°F to +212°F)
Kalrez –20°C...+100°C (–4°F to +212°F)
EPDM –40°C...+100°C (–40°F to +212°F)
t-mass I (bonded seals):
EPDM –40°C...+130°C (–40°F to +266°F)
Nitrile –35°C...+130°C (–31°F to +266°F)
Kalrez –20°C...+130°C (–4°F to +266°F)
t-mass F:
–0.5...40 bar gauge (–7.25 to 580 psi gauge)
t-mass I:
–0.5...20 bar gauge (–7.25 to 290 psi gauge)
See "Measuring range" section. → Page 83 ff.
2 mbar (0.029 psi) maximum (without flow conditioner)
Pressure temperature curve to EN (DIN), stainless steel
PN 16/40
bar
45
40
PN 40
35
30
25
20
PN 16
15
10
5
0
-200 -100
0
100
200
°C
300
400
Proline t-mass 65
a0005240

Advertisement

Table of Contents
loading

Table of Contents