Technical data
Medium temperature range
116
10.1.9

Operating conditions: Process

Sensor:
Promass F, A, H, P:
–50 to +200 °C (–58 to +392 °F)
Promass F (high-temperature version):
–50 to +350 °C (–58 to +662 °F)
Promass M, I, S:
–50 to +150 °C (–58 to +302 °F)
Promass E:
–40 to +125 °C (–40 to +257 °F)
Seals:
Promass F, E, H, I, S, P:
No internal seals
Promass M:
Viton –15 to +200 °C ( –5 to +392 °F)
EPDM –40 to +160 °C (–40 to +320 °F)
Silicon –60 to +200 °C (–76 to +392 °F)
Kalrez –20 to +275 °C (–4 to +527 °F);
FEP sheathed (not for gas applications): –60 to +200 °C (–76 to +392 °F)
Promass A
No seals inlying.
Only for mounting sets with threaded connections:
Viton –15 to +200 °C ( –5 to +392 °F)
EPDM –40 to +160 °C (–40 to +320 °F)
Silicon –60 to +200 °C (–76 to +392 °F)
Kalrez –20 to +275 °C (–4 to +527 °F);
Proline Promass 83 MODBUS RS485