Description of Device Functions
112
BASIC FUNCTION SENSOR DATA SENSOR PARAMETER
SENSOR CONFIGURATION
(6882)
CABLE LENGTH
(6883)
POSITION SENSOR
(6884)
WIRE LENGTH
(6885)
SENSOR DISTANCE
(6886)
ARC LENGTH
(6887)
PATH LENGTH
(6888)
Functional description
Use this function to select the configuration for the ultrasonic sensors, e.g. the number
of traverses (in the Clamp On version).
!
Note!
This function is not available unless one of the following options was selected in the
function MEASUREMENT (6880):
• CLAMP ON
• SOUND VELOCITY LIQUID
• INSERTION (is not supported by the measuring device)
Options
1)
NO. TRAVERSE: 1
2)
NO. TRAVERSE: 2
3)
SINGLE PATH
(is not supported by the measuring device)
3)
DUAL PATH
(is not supported by the measuring device)
Factory setting
NO. TRAVERSE: 2
1)
This option is not available unless CLAMP ON or SOUND VELOCITY LIQUID
was selected in the function MEASUREMENT.
2)
This option is not available unless CLAMP ON was selected in the function
MEASUREMENT.
3)
This option is not available unless INSERTION was selected in the function
MEASUREMENT.
!
Note!
The setting "NO. TRAVERSE: 2" is required for sensors with a nominal diameter range
from DN15 to DN 65.
Use this function to select the length of the sensor cable.
Options
LENGTH 5 m/15 feet
LENGTH 10 m/30 feet
Factory setting
LENGTH 5 m/15 feet
Use this function to view the position of both sensors on the rail.
User interface
5-digit number combination
The wire length for assembling the sensors at the correct distance apart appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
The distance between sensor 1 and sensor 2 as a length measurement appears on the
display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
The arc length on the pipe appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)
The path length appears on the display.
User interface
max. 5-digit number, including unit (e.g. 200 mm)