Safety Instructions; Designated Use; Installation, Commissioning And Operation; Operational Safety - Endress+Hauser Proline Prosonic Flow 93T Portable Operating Instructions Manual

Portable ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 93T Portable:
Table of Contents

Advertisement

Proline Prosonic Flow 93T Portable
Endress+Hauser
1

Safety instructions

1.1

Designated use

The measuring device described in these Operating Instructions is to be used only for measuring the
flow rate of liquids in closed pipes.
Examples:
• Acids, alkalis, paints, oils
• Liquid gas
• Ultrapure water with low conductivity, water, wastewater
As well as measuring the volume flow, the sound velocity of the fluid is also always measured.
Different fluids can be distinguished or the fluid quality can be monitored.
The designated operation of the measuring device is battery operation without connection to the
charger.
Resulting from incorrect use or from use other than that designated the operational safety of the
measuring devices can be suspended. The manufacturer accepts no liability for damages being
produced from this.
1.2

Installation, commissioning and operation

Note the following points:
• Installation, connection to the electricity supply, commissioning and maintenance of the device
must be carried out by trained, qualified specialists authorized to perform such work by the
facility's owner-operator.
The specialist must have read and understood these Operating Instructions and must follow the
instructions they contain.
• The device must be operated by persons authorized and trained by the facility's owner-operator.
Strict compliance with the instructions in these Operating Instructions is mandatory.
• Endress+Hauser is willing to assist in clarifying the chemical resistance properties of parts wetted
by special fluids, including fluids used for cleaning.
However, small changes in temperature, concentration or the degree of contamination in the
process can result in changes to the corrosion resistance properties. Therefore, Endress+Hauser
cannot guarantee or accept liability for the corrosion resistance properties of wetted materials in
a specific application.
The user is responsible for choosing suitable wetted materials in the process.
• The storage batteries for the device may only be charged with the charger supplied. Other
equipment could cause the battery to overheat (risk of fire!).
• Invariably, local regulations governing the opening and repair of electrical devices apply.
1.3

Operational safety

Note the following points:
• The transmitter having the ingress protection IP 40 is intended for operation in dry, clean and
non-hazardous environment. Mechanical stresses are to be avoided.
• The measuring device complies with the general safety requirements in accordance with
EN 61010-1 and the EMC requirements of IEC/EN 61326 during storage battery operation.
• The manufacturer reserves the right to modify technical data without prior notice. Your
Endress+Hauser distributor will supply you with current information and updates to these
Operating Instructions.
Safety instructions
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Prosonic Flow 93T Portable and is the answer not in the manual?

Questions and answers

Table of Contents