Danfoss FC 300 Design Manual page 66

0,25 kwt - 1,2 mwt
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

4 AutomationDrive FC 300 Selection
Mains Supply 3 x 380 - 500 VAC
AutomationDrive
FC 302
High/ Normal Load*
Typical Shaft output
at 400 V [kW]
Typical Shaft output
at 460 V [HP]
Typical Shaft output
at 500 V [kW]
EnclosureIP21, 54
without/ with options
cabinet
4
Output current
Continuous
(at 400 V) [A]
Intermittent (60 sec
overload)
(at 400 V) [A]
Continuous
(at 460/ 500 V) [A]
Intermittent (60 sec
overload)
(at 460/ 500 V) [A]
Continuous KVA
(at 400 V) [KVA]
Continuous KVA
(at 460 V) [KVA]
Continuous KVA
(at 500 V) [KVA]
Max. input current
Continuous
(at 400 V ) [A]
Continuous (at 460/
500 V) [A]
Max. cable size,mo-
tor [mm
Max. cable
size,mains F1/F2
[mm
Max. cable
size,mains F3/F4
[mm
Max. cable size, load-
sharing [mm
(AWG
Max. cable size,
brake [mm
Max. external mains
fuses [A]
Estimated power loss
at 400 V [W]
Estimated power loss
at 460 V [W]
F3/F4 max. added
losses A1 RFI, CB or
Disconnect, & con-
tactor F3 & F4
Max. panel options
losses
Weight,
enclosure IP21, IP 54
[kg]
Weight Rectifier
Module [kg]
Weight Inverter Mod-
ule [kg]
Efficiency
Output frequency
Heatsink overtemp.
trip
Power card ambient
trip
* High overload = 160% torque during 60 s, Normal overload = 110% torque during 60 s
66
P450
HO
NO
450
500
600
650
530
560
F1/ F3
800
880
1200
968
730
780
1095
858
554
610
582
621
632
675
779
857
711
759
2
(AWG
2)
)]
2
(AWG
2)
)]
2
(AWG
2)
)]
2
2)
)]
2
(AWG
2)
)
1600
1
9492
10647
4)
8730
9414
893
963
1004/ 1299
102
102
4)
MG.33.BC.02 - VLT
P500
P560
HO
NO
HO
NO
HO
500
560
560
630
630
650
750
750
900
900
560
630
630
710
710
F1/ F3
F1/ F3
880
990
990
1120
1120
1320
1089
1485
1232
1680
780
890
890
1050
1050
1170
979
1335
1155
1575
610
686
686
776
776
621
709
709
837
837
675
771
771
909
909
857
964
964
1090
1090
759
867
867
1022
1022
8x150
(8x300 mcm)
8x240
(8x500 mcm)
8x456
(8x900 mcm)
4x120
(4x250 mcm)
4x185
(4x350 mcm)
2000
10631
12338
11263 13201 13172 15436
9398
11006 10063 12353 12332 14041 13819 17137 15577 17752
951
1054
978
1093
1092
400
1004/ 1299
1004/ 1299
1004/ 1299
102
102
102
102
0.98
0-600 Hz
95 °C
68 °C
®
is a registered Danfoss trademark
FC 300 Design Guide
P630
P710
P800
NO
HO
NO
HO
710
710
800
800
1000
1000
1200
1200
800
800
1000
1000
F1/ F3
F2/ F4
F2/ F4
1260
1260
1460
1460
1386
1890
1606
2190
1160
1160
1380
1380
1276
1740
1518
2070
873
873
1012
1012
924
924
1100
1100
1005
1005
1195
1195
1227
1227
1422
1422
1129
1129
1344
1344
12x150
(12x300 mcm)
6x185
(6x350 mcm)
2500
14967 18084 16392 20358
1230
2067
2280
2236
1246/ 1541
1246/ 1541
102
136
136
136
102
102
NO
1000
1350
1100
1720
1892
1530
1683
1192
1219
1325
1675
1490
2541

Advertisement

Table of Contents
loading

Table of Contents