Danfoss FC 300 Design Manual page 147

0,25 kwt - 1,2 mwt
Hide thumbs Also See for FC 300:
Table of Contents

Advertisement

FC 300 Design Guide
Illustration 7.33: Mounting of bottom plate,frame size E1.
The bottom plate of the E1 can be mounted from either in- or outside of the enclosure, allowing flexibility in the installation process, i.e. if mounted from
the bottom the glands and cables can be mounted before the frequency converter is placed on the pedestal.
7.2.9 IP21 Drip Shield Installation (Frame size D1 and D2 )
To comply with the IP21 rating, a separate drip shield is to be
installed as explained below:
Remove the two front screws
Insert the drip shield and replace screws
Torque the screws to 5,6 Nm (50 in-lbs)
MG.33.BC.02 - VLT
®
is a registered Danfoss trademark
7 Mechanical Installation - Frame size D, E and
Illustration 7.34: Drip shield installation.
F
7
147

Advertisement

Table of Contents
loading

Table of Contents