Non-Volatile Latches (Nvlat); Oscillography (Osc) - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
FlxLgcGAPC1
LNName:
data attribute
data obj.
stVal
Idξ
setVal

3.5.6.7 Non-volatile latches (NVLat)

This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60).
Table 3-115: Non-volatile latch data objects
3
NVLatGAPC#
LNName:
data attribute
data obj.
Ind1
stVal
Ind2
stVal
InRef1
setSrcRef
setSrcCB
InRef2
setSrcRef
setSrcCB

3.5.6.8 Oscillography (Osc)

This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60).
Table 3-116: Oscillograph data objects
OscRDRE1
LNName:
data attribute
data obj.
RcdMade
stVal
FltNum
stVal
units
units.SIUnit
units.multiplier
NumCycPe
r
stVal
units
units.SIUnit
units.multiplier
RsTms
stVal
units
units.SIUnit
units.multiplier
RcdTrg
3-126
Gen
LDevice inst:
Type
FC UR Name
ST VOξ On
BOOLEAN
VSG
SP The first twelve characters are
VISIBLE
STRING255
mapped to setting VIRTUAL
OUTPUT ξ ID
Gen
LDevice inst:
Type
FC UR Name
SPS
ST LATCH # ON
BOOLEAN
SPS
ST LATCH # OFF
BOOLEAN
ORG
SP Non-Volatile Latch SET setting
ObjectReference
SP
ObjectReference
ORG
SP Non-Volatile Latch RESET setting Reference to the data attribute to input
ObjectReference
SP
ObjectReference
Gen
LDevice inst:
Type
FC UR Name
SPS
ST
BOOLEAN
INS
ST NUMBER OF TRIGGERS actual
INT32
value
CF
Unit
ENUMERATED
ENUMERATED
INS
ST Actual value CYCLES PER RECORD
INT32
CF
Unit
ENUMERATED
ENUMERATED
INS
ST Actual value LAST CLEARED DATE
INT32
CF
Unit
ENUMERATED
ENUMERATED
SPC
CHAPTER 3: IEC 61850 COMMUNICATION
UR element:
Description
This setting is used to describe virtual
output ξ
Non-Volatile Latches element #
UR element:
Description
LATCH # ON operand value
"LATCH # OFF operand value
Non-Volatile Latch LATCH # SET setting
Reference to the data attribute to input
Source GoCB of input if via GOOSE
Non-Volatile Latch LATCH # RESET setting
Source GoCB of input if via GOOSE
Oscillography, core logical node
UR element:
Description
Records are available
NUMBER OF TRIGGERS actual value
1, the code for dimensionless
0, the code for a multiplier of 1
CYCLES PER RECORD actual value
1, the code for dimensionless
0, the code for a multiplier of 1
LAST CLEARED DATE actual value
4, the code for time
0, the code for a multiplier of 1
External command to trigger recorder
UR SERIES – COMMUNICATIONS GUIDE
FlexLogic
R/W/C
R
R
R
R/W/C
R
R
R
R
R
R/C
R/C
R
R/C
R/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/Ctrl

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents