Security Supervisory (Read/Write Setting); Security Command (Read/Write Command); Security Reserved Modbus Registers (Read/Write); Neutral Current Unbalance Commands And Actual Values - GE UR Series Manual

Hide thumbs Also See for UR Series:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
Security (Read/Write Setting)
All
32D4
Security (Read Only)
All
32DE
Security (Read/Write)
All
32DF
2
Security (Read Only)
All
32E9
"
3328
Security (Read/Write Setting)
All
3329
"
332A
"
332B
"
332C
"
332E

Security Supervisory (Read/Write Setting)

All
3331
"
3332
"
3333
"
3334
"
3335
"
3336
"
3337
"
3338
"
333A

Security Command (Read/Write Command)

All
3350
"
3351
"
3352
"
3353

Security Reserved Modbus Registers (Read/Write)

All
3360
"
3374
Security Reserved Modbus Registers (Read Only)
All
3375
Event Recorder (Read Only)
All
3400
"
3402
"
3404
Event Recorder Commands (Read/Write Command)
All
3406
Neutral Current Unbalance Commands and Actual Values (Read/Write Unless Noted) (3 Modules)
C70
3410
"
3411
2-38
Observer Alphanumeric Password Setting
Observer Alphanumeric Password Status
Observer Alphanumeric Password Entry
Reserved for password settings of future
roles (63 items)
Security Status Indicator
Session Lockout
Session Lockout Period
Load Factory Defaults
Syslog Server IP Address
Syslog Server Port Number
Device Authentication Enable
Supervisor Role Enable
Lock Relay
Factory Service Mode Enable
Failed Authentication Alarm Enable
Firmware Lock Alarm
Settings Lock Alarm
Bypass Access
Serial Inactivity Timeout
Operator Logoff
Engineer Logoff
Administrator Logoff
Clear Security Data
Address 0x3360 reserved for serial login (20
items)
Address 0x3374 reserved for serial logout
Address 0x3374 reserved for serial logout
Events Since Last Clear
Number of Available Events
Event Recorder Last Cleared Date
Event Recorder Clear Command
Neutral Current Unbalance Automatic
Setting Function
Neutral Current Unbalance Apply
Magnitude
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
---
---
---
0 to 1
---
1
---
---
1
0 to 65535
---
1
0 to 65535
---
1
0 to 99
---
1
0 to 9999
min
1
0 to 1
---
1
0 to 4294967295
---
1
1 to 65535
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 3
---
1
1 to 9999
min
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 1
---
1
0 to 9999
---
1
0 to 9999
---
1
0 to 5
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 2
---
1
0 to 1
---
1
UR SERIES – COMMUNICATIONS GUIDE
Format
Default
F202
(none)
F102
0 (Disabled)
F202
(none)
F001
0
F618
0
F001
3
F001
3
F126
0 (No)
F003
0
F001
514
F126
1 (Yes)
F102
0 (Disabled)
F102
0 (Disabled)
F102
0 (Disabled)
F102
1 (Enabled)
F102
1 (Enabled)
F102
1 (Enabled)
F628
0 (Disabled)
F001
1
F126
0 (No)
F126
0 (No)
F126
0 (No)
F126
0 (No)
F001
3
F001
3
F617
3 (Engineer)
F003
0
F003
0
F050
0
F126
0 (No)
F092
0 (Disabled)
F126
0 (No)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents